Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.XX Environment: Windows 7 (64 bit) & others Area: Settings/Attributes Subarea: Isometric Content - Labels Original Author: Rahul Kumar, Bentley Product Advantage Group To use various option to display indexing for flanges bolts and Gaskets in OpenPlant Isometrics Manager. Background In some project indexing is required to show in single bubble or Box for each component. See image below for default setup with latest OpenPlant Isometrics Manager version 08.11.11.101. to change various symbols and settings, see below steps for further help. Below steps can be used using both AutoPLANT Modeler-OpenPlant Isometrics Manager & OpenPlant Modeler-OpenPlant Isometrics Manager. Check below shown in both case. OpenPlant Modeler-OpenPlant Isometrics Manager Steps to Accomplish Launch OpenPlant Isometrics Manager. Select Project unit, say Metric here. Click on “Configuration” Icon to launch Isometric configuration dialog box. From Isometric configuration dialog, select “Advanced” node and click on “Explore Style” option. Inside “config” folder, open style.xml file. Search for and set various option as per requirement. Few of them are highlighted for reference. See image below. To use labels without prefix - Set True to False . See image below. See in Isometric- To change prefix for regional use - (e.g in German it represents as F,D,S Flansch, Dichtung & Schrauben (Indexes F, D & S). Change settings as shown in below image. See in Isometric- To Change its bubble shape - Set Cell name NOTE_CIRCLE as shown in below image. See Isometric - To Consolidate Fastener Label in one Box- Set GroupInSingleLabel as shown below. See Isometric - AutoPLANT Modeler-OpenPlant Isometrics Manager Steps to Accomplish Open " Isometric configuration " through Project Administrator. Select Settings option and click on " Create/Modify " option. In Isometric Configuration window select the desired Style. Click on Advanced Option and select Explore Style. In “ config ” folder, open style.xml file. Search for and set various option as per requirement. Few of them are highlighted for reference. See image below. To use labels without prefix - Set True to False . See image below. . See in Isometric:- To change prefix for regional use - (e.g in German it represents as F,D,S Flansch, Dichtung & Schrauben (Indexes F, D & S). Change settings as shown in below image. See in Isometric To Change its bubble shape - Set Cell name NOTE_CIRCLE as shown in below image. See in Isometric To Consolidate Fastener Label in Single Box- Set GroupInSingleLabel as shown below. See in Isometric See Also Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧