Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX & Higher Environment: Windows 7/8/10 (64 bit) Area: Customization Subarea: Original Author: Harpreet Singh, Bentley Product Advantage Group Background This article will explain the procedure of making a valve replaceable in OpenPlant PID. For this article we will take the example of CHECK_VALVE class. With default configuration this valve is not replaceable but with the help of below steps it can be made replaceable. As shown above replace command is not available in context menu. Steps to Accomplish Open Class Editor and load OpenPlant_PID schema. Supplement it with OpenPlant_PID_Supplemental_Imperial schema. Go to CHECK_VALVE class. Locate Component Custom Attribute on class tab. Change Replace Enabled to True in custom attribute. Save the changes and verify the result. Replace command is now available in context menu. Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!
↧