Forum Post: RE: When placing a slip-on flange and using a field-fit weld Create Iso via OPIM dimensions to the cut end of the pipe. Is there a way to dimension to the face of flange instead?

$
0
0
Hello Steven, you can skip the dimension by checking off dimension field welds option available under Dimensioning option. See images below. Current Isometric Check off option present under "Component Dimensions" area. Desired Isometric HTH -Regards | Rahul Kumar