Wiki Page: "Olemanager was not found"Error while loading Support Topwork Browser and Componet Preference

$
0
0
Applies To Product(s): AutoPlant Modeler / Piping Version(s): 08.11.09.XXX Environment: Windows 7 64 bit and others Area: Settings/Attributes Subarea: Original Author: Abhijit Bute, Bentley Product Advantage Group Overview In Autoplant Piping when load support topwork browser or component preference user may face following error. " OleManager was not found " Problem Description When user install uninstall older of autoplant and install new version of Autoplant. "Unable to find Olemanager" error occured while loading support topwork browser or component preference. This error because of older versions of Autoplant traces available in registry. Following steps will helps to get rid of error message. Steps to Resolve Note: Kindly make sure that all registry are backup properly. 1. Open registry editor in admin mode. 2. Go to following path. HKEY_CLASSES_ROOT\Wow6432Node\CLSID\{85D0E0D6-E7E5-4123-AFE5-35A49E9A4B8A} HKEY_CLASSES_ROOT\CLSID\{85D0E0D6-E7E5-4123-AFE5-35A49E9A4B8A} HKEY_CLASSES_ROOT\CLSID\{720080E7-D479-4053-94B3-112B9809698B} HKEY_CLASSES_ROOT\Wow6432Node\CLSID\{720080E7-D479-4053-94B3-112B9809698B} 3. Delete older version entries and keep current Autoplant version entries. 4. Open AutoPlant and try to load support browser. 5. If still same error persist then try further steps 6. Try to register "Olenmanager.dll" by following steps. For Autoplant Modeler version SS5 and above Run CMD as administrator and use the following commands. Insert to CMD cd C:\Program Files (x86)\Bentley\Plant v8i\Bin\NGUtils\x86\ Press Enter Insert to CMD C:\Windows\Microsoft.NET\Framework\v4.0.30319\RegAsm.exe /codebase OleManager.dll Press Enter For Autoplant Piping version SS4 and below versions. Run CMD as administrator and use the following commands. Insert to CMD cd C:\Program Files (x86)\Bentley\Plant v8i\Bin\NGUtils\x86\ Press Enter Insert to CMD C:\Windows\Microsoft.NET\Framework\v2.0.50727\RegAsm.exe /codebase OleManager.dll Press Enter 7. Open AutoPlant and try to load support browser. 8. If still problem persist please refer following communities link steps. Still a Problem? If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround. Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

Viewing all articles
Browse latest Browse all 12277

Trending Articles