Wiki Page: "Error Copying Document to the Client" While Loading I-model

$
0
0
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Projectwise Interoperability Subarea: Original Author: Harpreet Singh, Bentley Product Advantage Group Problem Description Below error shows up when loading I-model from Projectwise managed workspace in OpenPlant Isometrics Manager. Steps to Resolve Launch PW Admin and login to the datasource as an admin. Go to users and select the user who is getting this error. Right click on the user name and open the properties. Switch to Settings tab and double click Documents option. Toggle " Leave local copy on check in " option as highlighted below. Launch OpenPlant Isometrics Manager again and load I-model to verify result. Still a Problem If there is still some problem, then please create a Service Request and contact Bentley Product Advantage group along with the list of all relevant details to get in depth analysis and for possible solution or workarounds. See Also Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!