Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Errors-Logs-Messages Subarea: Settings/Attributes Original Author: Rahul Kumar, Bentley Product Advantage Group Overview In OpenPlant Isometrics Manager, during isometrics generation it displays error as Error:[5] DWG creation failed. Problem Description In OpenPlant Isometrics Manager, when “ Isometric Output Format ” option selected as DWG like shown in below image. When user generates an isometrics then following error prompts as shown below. Error:ERROR[5]: DWG creation failed at Bentley.Isometrics.IsoExtWrapper.GenerateIsometrics.Execute() at Bentley.Isometrics.IsoProduction.PipeGenerateIso.Process(IsometricInstance isoInst) at Bentley.Isometrics.IsoProduction.ProcessingPipes.ProcessIsoInstance(BackgroundWorker bWorker, IsometricInstance isoInst, Boolean& success) Below steps will aid user to avoid such errors. Below example and error caused shown here using OpenPlant Modeler and OpenPlant Isometrics Manager. However similar instances might occur using AutoPLANT modeler and OpenPlant Isometrics Manager. OpenPlant Modeler-OpenPlant Isometrics Manager Steps to Resolve The above errors mentioned due to missing file present inside the “ dwgdata “ folder which is found under each styles for isometrics. See image below. Note - For default project - (C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\Projects\OPModeler_Metric\DataSet\Isometrics\Styles\IFC) User has to check file defined inside the OpenPlant Modeler. See default dwgdata folder below where all files are present. Update the missing file to working style folder under “ dwgdata ” folder & verify results. See below image after putting all relevant files. AutoPLANT Modeler-OpenPlant Isometrics Manager Steps to Resolve The above errors mentioned due to missing file present inside the “ dwgdata “ folder which is found under each styles for isometrics. See image below. User has to check file defined inside the OpenPlant Modeler. See default dwgdata folder below where all files are present. Update the missing file to working style folder under “ dwgdata ” folder & verify results. See below image after putting all relevant files. Still a Problem? If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround. See Also Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!
↧