Forum Post: RE: Adding the Pipe NOMINAL_DIAMETER to Support Location OPM

$
0
0
Hi Ray, Since NOMINAL_DIAMETER on SUPPORT class is also Numeric (Double) property and therefore EC Expression will not work in this case. We are hoping to get this fixed in future versions. However, as a workaround you can create new String property on SUPPORT class and use same expression on it which will work correctly. Similar example has been used in above wiki article where NOMINAL_DESIGN_TEMPERATURE is double on PIPELINE but a string property has been added on SUPPORT class to get the value. Hope this helps! Regards, Harpreet