Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.xxx Environment: Windows 7 (64 bit) Area: Component Subarea: - Original Author: Harpreet Singh, Bentley Product Advantage Group Problem Description During PSDS conversion, LAP_JOINT_STUB_END does not convert from PSDS Spec to OpenPlant Modeler Spec. Steps to Resolve Launch Class Editor from start menu. Open OpenPlant_CustomAttributes.08.11 by navigating to folder \\WorkSpace\OPModeler\schemas . Again open OpenPlant_3D.01.06 by navigating the project folder. Supplement this with two schema’s OpenPlant_Catalogue_Supplemental_Mapping_PSDS.01.06 & OpenPlant_3D_Supplemental_Modeling.01.06 schema. Go to LAP_JOINT_STUB_END class. Right click on LAP_JOINT_STUB_END class and add 'PSDS Class Map' custom attribute. Add values in the custom attribute as shown below. Save the changes in schema and open mapping database file from \\%Project Root%\Dataset\Mapping Databases\ folder as highlighted in below snapshot. Add new mapping in MAPPING_INFO table as highlighted in the below picture. Save the changes in mapping database and re-launch spec gen. See Also Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧