Dear all, 1. we are using OPM Version 440. In the spec I have defined the bolts according the Definition. For DN 50 it Looks as follows: DN 50 PN25 100322978 SHRBLZ 17709/17218 M16X 80 2510 L/NF DN 50 PN25 100322980 SHRBLZ 17709/17218 M16X 90 2510 L/NF so I have two different lengths of 80 and 90 mm. Bolt of length 80mm should be used for FL-FL Connections and 90mm for FL-WAFER-Comp-FL Connections. While placing a flange couple though I have the possibility to Chose between the two bolts via the spec grid as you can see below: so the calculated length must be under 80 mm and I can Choose between the two values 80 and 90. I guess this is the Default Setting. Is there any possibility though to force OPM to choose the bolt with the Minimum applicable length in this case the 80mm bolt? 2. How can I see the bolt properties, for all other component it is just a double click on the element but for bolts I can only see them in the item browser? It is very difficult to associate the bolt in the model with the entries in the item browers Thanks a lot for your Support. Best regards
↧