Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10( 64 bit) Area: Settings/Attributes Subarea: Modify symbols in OpenPlant Isometrics Manager Original Author: Berrie Geboers, Bentley Product Advantage Group Overview User want to extend the distance between valves in 4 way level gauges symbol. (Level_GAUGE47FL) Steps to Resolve Go in Windows Explorer “Your Project” \Config\OpenPlant\Isometrics\styles\IFC\config and copy the symbolsizes.def as back up. Open the original file and search for RETURN4 (This is the IE_SCALERTYPE of that symbol.) Edit the component in the definition file as follows) DEF RETURN2 RETURN2 SEGLEN 16 16 8 8 82 (this is an example value of 50) Save the file. Go to: “Your Project\Config\OpenPlant\Isometrics\styles\IFC\cell and open the custom.cel Import the correct symbol from the lisocomp.cel. (Level_GAUGE4FL) Now move the selected items 50 (distance) to the left and reconnect the horizontal lin. Save the file. Run an Iso from a 4 flanged level gauge. Still a Problem? If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround. See Also Comments or Corrections? Bentley's Product Advantage Group requests that you
↧