Hello Luis, I have tested your described situation and on my side everything works fine. How are you connecting these components? How are you connecting L1 Pipe>Flange>Gasket>Bolt>Valve Pipe? I can't place components by this order, because Gasket and bolts are placed only when connecting to other component and using connective component's data. Give us here more information how are you connecting these components. I have placed L100 pipe and connected a weld neck flange to it. Then I have changed LineNumber and connected Valve>Flange>Pipe. Bolts and gaskets were placed automatically. Gasket and bolt is placed using connective components data, so if you will place flange and connect valve to it, gaskets and bolts will inherit valve's data. If you will try connect new flange to valve, gasket and bolt will inherit flange's data. Check your components placement order. it should be: Place Line 2 (Pipe>Flange) and then connect Line 1 (Gaskets/Bolts>Valve>Gaskets/Bolts>Flange>Pipe) Hope this information will be useful. Looking forward to hearing from you. Regards, Kestutis M.