Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64-bit) Area: OpenPlant Isometrics Manager Subarea: Iso-Generation Original Author: Deepak Singh,Bentley Product Advantage Group Overview To remove PartID prefix from spectacle blind. Problem Description In OpenPlant Isometrics Manager, user wants to remove PartID prefix for spectacle blind. Currently in generated isometrics spectacle blinds shows prefix as shown below. Here requirement is to remove prefix “F” & only to show number for spectacle blind. Steps to Resolve Using Bentley Class Editor , open OpenPlant_3D.01.07. ecschema of your particular project. Supplement with OpenPlant_3D_Supplemental_Modeling.01.07. ecschema, OpenPlant_3D_Supplemental_ModelingViews.01.07. ecschema & OpenPlant_3D_Supplemental_Isometrics_Isoextractor.01.07. ecschema For More information on supplementing schema click here>>>> Navigate to Spectacle Blind class, search Isometric Component custom attribute as shown below. Change Class Name from CT_FLANGE to CT_SPACER as shown below. Class Name = CT_SPACER Save all the changes & verify the results as shown below. See Also Still a Problem? If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround. Comments or Correction? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧