Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: Original Author: Rahul Kumar, Bentley Product Advantage Group Overview OpenPlant Isometrics Manager generates an E rror[0]:SYS mismatch CP/CP count: component ID = 1 Problem Description With user defined class as TEST_3_STAGE under Multistage Valve, while generating isometrics. It reports an error. See below. E rror[0]:SYS mismatch CP/CP count: component ID = 1 Reason On Defining new class, it is also required to be present inside the ipscript.txt file. Adding the class under each stage in ipscript.txt file would solve the purpose.Below solution has been described using OpenPlant Modeler & OpenPlant Isometrics Manager. Steps to Resolve Request IT admin to provide the required permission to access the folders to modify ipscript.txt file. Check Default path: C:\Program Files (x86)\Bentley\OpenPlantIsometricsManager V8i\OpenPlantIsometricsManager\config Open ipscript.txt file. Add new class TEST_3_STAGE with existing classes. See image below. Save & Close file. Launch OpenPlant Isometrics Manager. Generate DWG and verify results. See image below. Still a Problem? Error[0]: SYS mismatch CP/CP count error might occur with different conditions, which can be further added & discussed in this article. If above problem still persist, then please create a Service Request and contact Bentley Product Advantage group along with the list of all relevant details to get in depth analysis and for possible solution or workarounds. See Also Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧