Applies To Product(s): AutoPLANT Modeler Version(s): 08.11.11.XXX (SS6), 08.11.12.XXX (SS7), 08.11.13.XXX (SS8) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: Original Author: Berrie Geboers, Bentley Product Advantage Group Background When placing Equipment, in example a Vertical vessel and you set the size for parameter B to 35000 you will get an error as shown below. This means that the value of 35000 exceeds the maximum defined in the Equipment limits file. These values can be found in “Your Project”\Config\equip\ limits.ini file. Steps to resolve To avoid the message and make it possible to created lager Equipment’s, go to the menu Equipment>Setup>Drawing Preferences and check on the box “Override Limits. After clicking on OK, you see a dialog, confirming this setting. Now it is possible to create larger Equipment. Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧