Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX (SS5) | 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Custom Component Subarea: Original Author: Harpreet Singh, Bentley Product Advantage Group Problem Description Sometimes when custom component have graphics which extend beyond connection points then pipe run doesn't connect properly when component is placed inline and thus leaves behind a gap as shown below. Steps to Resolve Launch Class Editor and load OpenPlant_PID schema. Supplement it with OpenPlant_PID_Supplemental_Imperial schema. Navigate to the class, CUSTOM_VALVE in this case. Right click on the class and select Add/Remove Custom Attribute option. Add 'Schematics Component Custom Attributes' on this class. Set 'Use Predefined Points for Range' field to True as shown below. Save the changes and verify results in OpenPlant PID. Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!
↧