Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64-bit) Area: OpenPlant Isometrics Manager Subarea: Iso-Generation Original Author: Deepak Singh,Bentley Product Advantage Group Overview To add prefix "M" for bolt size in bill of material. Problem Description In OpenPlant Isometrics Manager, user wants to add prefix "M" for size of bolts.This can be achieved by creating a new report for bolt in report definition file of respective style folder. Note: To see the correct result ensure that during modeling bolt diameter sizes are in metric unit. Steps to Reproduce Open report.def file of your particular style folder. Scroll down to FLD report. Exclude bolt from this report, see below image. EXCLUDE = IE_TYPE=CT_WELD|CT_BOLT Create a new BOLT report, to add prefix M, concatenate M with SIZE refer below image. REPORT = BOLT EXCLUDE = IE_TYPE=CT_WELD|CT_GASKET INCLUDE = IE_TYPE=CT_BOLT COLUMN = 3: R : PARTID COLUMN = 20: L : "M"+SIZE COLUMN = 7: R : QUANTITY COLUMN = 60: W : IE_DESCRIPT COLUMN = 2: GROUP = PARTID SORT = PARTID:N SEP = @ SORTHEADERS = 1 Modify combi report, refer below image. Save settings and verify the result as shown below. See Also Still a Problem? If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround. Comments or Correction? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧