Quantcast
Viewing all articles
Browse latest Browse all 12277

Wiki Page: To Define Arc Length for Pipe Bends in OpenPlant Modeler

Applies To Product(s): OpenPlant Modeler Version(s): 08.11.11.87(SS6) & Above Environment: Windows 7 (64 bit) & Others Area: Properties Subarea: Pipe Bend - Arc Length Original Author: Rahul Kumar, Bentley Product Advantage Group Overview To Defined Arc length for Pipe Bends in OpenPlant Modeler. Problem Description In OpenPlant Modeler, it has been observed that Length Property for pipe bend calculation displays as twice the arm length of bend, i.e. Length = 2 * Pipe Bend radius along with clamp length (Length to Bend Point, Length after Bend Point). See image below for default calculation in OpenPlant Modeler. Length = Length to Bend Point + 2 * Pipe Bend radius + Length After Bend Point. Where, Length to Bend Point = 100 mm Length after Bend Point = 100 mm Pipe Bend radius = 150 mm Length = 100 + 2*150 + 100 = 500 mm Actual calculation should be, where, D = Diameter of Pipe Note – In OpenPlant Modeler unit conversion 1” = 25mm hence desired value would be, = 1.5*4 *25*PI/180*90 = 235.619mm Considering Length to Bend Point = 100 mm & Length after Bend Point = 100 mm, Updated length would be = 100 + 235.619 + 100 = 435.619 mm See below steps to overcome this situation by defining a new property in schema through class editor and applying the mathematical expression in EC expression. Steps to Resolve Launch OpenPlant Project Administrator. Select project unit of working. From Tools ->Select Class Editor to launch. Open “OpenPlant_3D.01.07.ecschema” and supplement it with below schema. “OpenPlant_3D_Supplemental_Modeling.01.07.ecschema” Navigate to class PIPE_BEND . Under property tab, use LENGTH Property. Copy LENGTH Property & paste it on same window to create a new property. Right click on LENGTH property. See image. Move to below in property list, right click on it to Paste. See image below. Rename it to ARC_LENGTH and other fields as per below image shown. Note – Set the TypeName to string. On ARC_LENGTH property, click on “ Custom Attributes ”-> Add/remove Check for custom attribute (CA) “ Caculated ECProperty Specification ”, pull it down in second dialog and set the location as shown in below image. Set the expression as shown in below image. LENGTH_TO_BEND+System.Math.PI*NOMINAL_DIAMETER*BEND_POINT_RADIUS*ANGLE/180+LENGTH_AFTER_BEND Save & Close the schema. Launch OpenPlant Modeler. Place a pipe bend with same value shown above to verify results. Still A Problem? If above problem still persist, then please create a Service Request and contact Bentley Product Advantage group along with the list of all relevant details to get in depth analysis and for possible solution or workarounds. See Also Comments or Corrections? Bentley's Product advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

Viewing all articles
Browse latest Browse all 12277

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>