Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit & Others Area: Settings/Attributes Subarea: Original Author: Abhijit Bute, Bentley Technical Support Group Background How to show Miscellaneous Attachment (Spool Identifier and Test Port Instrument Bubble) with tag number in isometric. Steps to Accomplish Open class editor and navigate to project path and open OpenPlant_3D ecschema. For ex.C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_METRIC\Config\ OpenPlant\schemas. Supplement schema with OpenPlant_3D_Supplemental_Isometrics_Isoextractor ecschema . Now, search " Note ” class found under Plant base object>Named Item . Under note class create new class by using “ Add derived class ” option. Assign name "Spool ID" or “Instrument_BUBBLE”. Now right click on this class and add AutoPLANT_PDW_Class_Map custom attribute. For Spool identifier edit the AutoPLANT_PDW_Class_Map custom attribute as in picture below. For Test Port Instrument Bubble add AT_ATTACH_TESTPORT ClassName. Now, Click On Properties, override TEXT property and edit AutoPLANT 3D Property name to " SPOOL " for Spool identifier or " TAGNUMBER " for Instrument Test Port. Click on Note class and from AutoPLANT_PDW_Class_Map custom attribute remove AT_ATTACH_SPOOLID for Spool identifier or AT_ATTACH_TESTPORT for Instrument Test Port. Save and close schema. Launch OpenPlant Isometrics Manager. Click on configuration button. See image below. Add new label " AP Spool ID " or " Instrument Bubble" here. Edit as per below image. Save and close. Generate isometric to review the result. Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧