Dears, i updated OPM Version 08.11.09.440(SS5) to the latest OPM Version 08.11.11.238(SS6). In the new Version of OPM I open dgn files created with the 440 er Version and publish an i-Model. This i-Model though can not be load into the new SS6 Version of the Open Plant Isometrics Manager (08.11.11.277). The error message is as follows: " [12.06.2017 12:34:23] Loading 1 i-models ======================================================================================================================== Starting i-model engine [12:34:23.5981169]Loading \\192.168.17.183\kunden\PMW\T\Projekte\R011189_3,5 bar Dampf\400 Planung\480 Rohrleitungsplanung\3D-Model\test.dgn.i.dgn [12:34:26.0473169]Error: Error while reading ECSchema 'OpenPlant_3D.01.04' Inner Exception=The class 'SUPPORT' requires class 'SUPPORT', which could not be found in schema 'OpenPlant.01.07'. [12.06.2017 12:34:26] Loaded 0 out of 1 i-models " The Problem seems to be file dependent, because in the same Environment modeling new lines and creating i-models works fine. In the Pipeline Manager I also did: "Validate Spec" and "Change Spec/Size" but without success. And the "OpenPlant.01.07" Schema of course contains a class "Support" Does anybody have an idea where the Problem can be? Thanks a lot
↧