Quantcast
Channel: OpenPlant | AutoPLANT
Viewing all articles
Browse latest Browse all 12277

Wiki Page: AutoISOGEN - Personal Isogen Error Codes

$
0
0
Product(s): AutoPlant AutoIsoGEN Version(s): Area: Other 0 Iso created successfully. 1 The PISOGEN environmental variable is not set 2 Invalid style name. The specified style cannot be found under the specified project. 3 Invalid project name. The specified project cannot be found under the specified isometric directory. 4 IDFGEN handshake failed - The handshake passed to IDFGEN has not been verified. 5 Obsolete - No longer used. 6 Obsolete - No longer used. 7 Obsolete - No longer used. 8 ISOGEN handshake failed - The handshake passed to ISOGEN has not been verified. 9 ISOGEN failed to produce a valid drawing. View message file for more details. 10 Obsolete - No longer used. 11 Obsolete - No longer used. 12 Obsolete - No longer used. 13 IDFGEN failed processing the PCF. View message file for more details. 14 Obsolete - No longer used. 15 Obsolete - No longer used. 16 Obsolete - No longer used. 17 Unable to copy the style's ISOGEN.FLS to the current working directory. 18 Obsolete - No longer used. 19 Personal ISOGEN handshake failed - The handshake passed to Personal ISOGEN has not been verified. 20 Unknown Error in Personal ISOGEN. An unexpected path through the program has occurred. 21 Unable to get the current working directory. 22 Unable to set the current working directory. 23 Invalid handshake mode. Error opening ISOGEN.FLS. Error opening message file. 24 Unable to restore the current working directory. 25 Error opening I-GEN.FLS for reading Error opening ISOGEN.FLS for writing Error opening options file specified in I-GEN.FLS Error closing options file specified in I-GEN.FLS Error closing I-GEN.FLS Error closing ISOGEN.FLS Error opening I-GEN.OPL for writing Error closing I-GEN.OPL 26 The isometric root directory is either blank or does not exist. 27 Unable to set PISOGEN environmental variable. 28 Invalid file extension 29 When running in IDFGEN mode, the input file must be a PCF. 30 Obsolete - No longer used. 31 Error occurred creating a POD (intermediate) file. Error occurred during "pass 1" when the input IDF file is pre-processed. 32 Error occurred creating a POD (intermediate) file. Error occurred during "pass 2" when the POD file is being created from Isogen data. 33 Failed to load PODGRAPHICS DLL – used in the creation of graphics output files such as DWG and IGR. 34 PODGRAPHICS process failed – i.e. a graphics specific process has failed – for example, user requested IGR output but SmartSketch is not installed. 35 The data supplied to the POD module is incorrect resulting in certain components not having any "intelligence". 40 41 Unable to get system temp directory. 42 Obsolete - No longer used. 43 Unable to set bore units to those specified in the input file. 44 Unable to perform macro substitution in style ISOGEN.FLS. 45 Unable to restore original style ISOGEN.FLS. 46 MESSAGE entry is missing from ISOGEN.FLS. 47 OPTION-SWITCHES-SHORT/LONG is missing from ISOGEN.FLS. 48 Failed to copy remote OPL file to local directory. 49 Failed to update ISOGEN.FLS. 50 Project disk is full – unable to create new output files. 51 File containing temp directory is full – unable to process files. 52 Unable to determine bore units from input file. 53 Unable to copy a file from the style directory to the current working directory. 60 The input file does not exist. 61 An invalid file was supplied to ISOGEN. It must be an IDF in ASCII or binary format. 62 ISOA2B conversion failed. Possibly a corrupt input file. 63 IDFGEN has reported that the input PCF has missing units. 64 IDFGEN has reported that the input file PCF has exceeded the size limit. 1001 Requested units combination is inconsistent – probably means a combination of metric bore and imperial co-ordinates. 1002 Obsolete - No longer used. 1003 Problem deleting an ISOGEN message file. 1004 Line in the options file has invalid format. 1005 Too many switches in the options file. 1006 Too few switches in the options file. 1007 Obsolete - No longer used. 1008 Obsolete - No longer used. 1009 Obsolete - No longer used. 1010 Obsolete - No longer used. 1011 Options file missing specified in ISOGEN.FLS is missing. 1999 Isogen has returned a FAIL for one or more drawings in the set. This means it has been unable to layout the drawing successfully. This is only a WARNING. 2001 Inconsistent units combination (imperial co-ordinates and metric bores). This is only a WARNING. 2022 IDFGEN has detected disconnected pipeline. Drawings have still been created that will indicate the cause of the disconnection. This is only a WARNING. 2022 -1 Error in Isogen data. Check message file. -2 Isogen dll failed to load (possible installation problem, missing dependent file etc) or crash occurred during execution, which has been trapped by the error handler. -3 Isogen thread failed to finish – possible execution loop which has been terminated by Personal Isogen -4 Isogen thread failed to finish – possible execution loop which has been terminated by Personal Isogen -5 Failed to load ISOGEN dll or any of its dependants. -6 Failed to load IDFGEN dll or any of its dependants such as Visual Fortran Runtime. -7 Idfgen dll has crashed during execution, which has been trapped by the error handler. The message file may give some more information. -1001 Failed to create the specified Pre/Post Processor. -1002 Pre/Post Processor has crashed. -1003 Pre/Post processor has timed out and the external process has been killed. -1004 Pre/Post processor has timed out but the external process cannot be terminated (and is therefore still running).

Viewing all articles
Browse latest Browse all 12277

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>