Applies to Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.404 (SS5) | 08.11.11.XXX (SS6) Environment: Wndows 7/8.1/10 (64-bit) Area Errors, Logs, Messages, Crashes Subarea Schema Customization Original Author Swapnil Joshi, Bentley Product Advantage Group= To Include Lug Type Bolts in Generated Isometric Background The schemas do not contain a mapping for lug type bolt. Hence we cannot generate the isometric of the model and get following error. AutoPLANT Modeler - OpenPlant Isometrics Manager Steps to Resolve Launch Bentley Class Editor. Open schema OpenPlant_3D.01.07 and supplement with OpenPlant_3D_Isometrics_IsoExtractor schema. Search for BOLT in the classes. Expand the BOLT node and select Piping Fastener Bolt Wafer. In the class tab, add the entry in the AutoPLANT_PDW_Class_Map. Navigate to the Bolt class. In the Bolt class go to AutoPLANT_PDW_Catalog_Class_Map. Add the entry as shown below. Class Name: AT_LUG_W_BOLT Module Name: BASE GType BOLT SType LUG Save the schemas and regenerate the isometric. This time there will be no error in generating isometric. See Also https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/31341/element-valve-has-valve-operating-device-is-missing-required-attribute-sourceclass Still a Problem? If the above problem still persist, then please create a Service Request and contact the Bentley Product Advantage Group. Please include a list of all relevant details to get in depth analysis for a solution or workaround. Comments and Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments and Corrections?" section. THANK YOU!
↧