Quantcast
Channel: OpenPlant | AutoPLANT
Viewing all articles
Browse latest Browse all 12277

Wiki Page: Configuring the BOM and Reports

$
0
0
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: - Original Author: Keith Couvillion, Bentley Product Advantage Group BOM / Report Configuration The material report on the drawing is controlled with the report definition file (report.def). This definition file provides a very flexible way of specifying the material output on the drawing. With the report definition file multiple reports can be defined which will always be processed any time a drawing is generated. Not all reports need to be included in the drawing. All reports become available as text files. At the discretion of the user these files can be used for various purposes. They may even be formatted in such a way that they can be used as input into the material handling system of the organization. Note - With Recent release of OpenPlant Isometrics Manager - Version 08.11.11.224 SS6 Refresh 2, Many things have been changed. Users are advised to take a notice on changes that has been made to facilitate the ease of use for customizing reports. This can be commonly check for both AutoPLANT Modeler-OpenPlant Isometrics Manager & OpenPlant Modeler-OpenPlant Isometrics Manager Report Definition Report Definition File From the Isometric Configuration dialog: Select the Isometrics Style tab Style – Select the relevant style from the dropdown Select Advanced from the left pane Click Open Report Definition Note: The header of the report definition file explains the available option to configure the content and layout of reports. Table Definitions The table layout of a material report is defined by COLUMN keywords. The column definition has the following syntax: COLUMN = : : COLUMN = 3: R : PARTID COLUMN = 19: R : QUANTITY COLUMN = 7: R : SIZE1 COLUMN = 7: R : SIZE2 COLUMN = 2: : COLUMN = 60: W : IE_DESCRIPT Where: specifies the width of the column in millimeters (Note: This has changed as it used to specify character count for the width) can be one of the following: L – left aligned C – centered R – right aligned W – wrap (a new line will be added if the length of the expression exceeds the width of the column is an expression for the content of the report column. Any component attribute or string can be used. Example: IE_DESCRIP + UUID + “and a string” would concatenate the attributes IE_DESCRIPT and UUID and the string “and a string.” Note: The COLUMN width field is now interpreted as a millimeter (MM) value instead of a character count. User may need to change their reports a bit. This allow user for easier settings. For More information click here>>>> Displayed Properties The COLUMN keyword specifies the properties to include and their sequence. In the example below, the PARTID property is the first property in the report, followed by the QUANTITY property. The properties are ordered from left to right in the report. COLUMN = 3: R : PARTID COLUMN = 19: R : QUANTITY COLUMN = 7: R : SIZE1 COLUMN = 7: R : SIZE2 COLUMN = 2: : COLUMN = 60: W : IE_DESCRIPT Table Headers To specify a fixed text as start of the report, use the TEXT keyword. Extra flexibility is provided with the WRITE keyword. The WRITE keyword writes the variable part of the report in between the fixed text from the TEXT keywords. Below is an example positioning the material table between a header and a single footer line: TEXT = @ ---------------------------------------------------------------- TEXT = @ PART | QUANTITY | SIZE1 | SIZE2 | DESCRIPTION TEXT = @ ---------------------------------------------------------------- WRITE = TEXT = @ ---------------------------------------------------------------- Bill of Material Location on Drawing The position of the Bill of material is defined by the position of its related text node. By default the text node number for the Bill of Material is set to 60. The text node number for the Pipe Cut List is set to number 61. These default numbers can be changed by changing the related property in the Bill of Material definitions file. Component Types Use the INCLUDE and EXCLUDE keywords to specify the type of elements that will be included in, or excluded from, the report. The example below includes only field items and excludes welds. INCLUDE = IE_FIELD=1 EXCLUDE = IE_TYPE=CT_WELD Field and Erection Materials To specify a report that only contains field components, specify the following line in the material report: INCLUDE = IE_FIELD=1 REPORT = FLD # this to include only field items INCLUDE = IE_FIELD=1 EXCLUDE = IE_TYPE=CT_WELD COLUMN = 3: R : PARTID COLUMN = 19: R : QUANTITY COLUMN = 7: R : SIZE1 COLUMN = 7: R : SIZE2 COLUMN = 2: : COLUMN = 60: W : IE_DESCRIPT GROUP = PARTID SORT = PARTID:N SEP = @ SORTHEADERS = 1 TEXT = @ ---------------------------------------------------------- TEXT = @ Field Materials TEXT = @ ---------------------------------------------------------- Write = END Grouping / Sorting Reports The grouping and/or sorting of the report contents is done by adding the GROUP and/or SORT keywords to the report definition. Each field in the column list can be used as grouping or sorting criteria. GROUP = PARTID SORT = PARTID:N Note: Removing the GROUP keyword will create a material list with each component on a separate line. Summarizing Reports To summarize the number of components that have been grouped together, use the QUANTITY keyword. COLUMN = 19: R : QUANTITY Combining Reports If you want to have a material list that first shows the shop items and then the field items, you can combine 2 reports into one. The example below combines a report named shp with a report named fld . #--------------------------------------------------------------------------- # The COMBI report combine the SHP and FLD report into a single report # and attaches it to textnode 60 in the isometric #--------------------------------------------------------------------------- REPORT = combi WRITE = shp TEXT = @ TEXT = @ WRITE = fld NODE = 60 END Enable/Disable Reports The appearance of a report on the drawing can be enabled or disabled. The placement and positioning of a report on the drawing is controlled by tying it to a text node element in the seed file. Adding or removing the NODE keyword to display or not display the report on the drawing. A ‘ # ’ can also be used to turn the line into a comment, causing the placement of the report to be disabled. Placement enabled: NODE = 60 Placement Disabled: # NODE = 60 Pipe Cut Length Report Include the Cut ID in the report To include the cut id of the pipe cut labels in your pipe cut report, specify the CUTID keyword for one of the columns. The NODE keyword specifies the location of the report in the drawing. #----------------------------------------------------------------------------- # The CUT report lists the pipe cut pieces # Attaches to text node 61 #----------------------------------------------------------------------------- REPORT = CUT INCLUDE = IE_TYPE=CT_PIPE|CT_BEND COLUMN = 6:C: CUTID COLUMN = 7:R:SIZE1 COLUMN = 21:R:QUANTITY COLUMN = 3:R: COLUMN = 80:W:IE_DESCRIPT GROUP = CUTID SORT = CUTID NODE = 61 END With use on New setting, Cut list for Reports overflows, click here>>>> for more details Enable the Placement of Pipe Cut Labels The User Labels section in the Configuration Manager is used to control the placement of Pipe Cut Labels in the drawing. From the Isometric Configuration dialog: Select the Isometrics Style tab Style – Select the relevant style from the dropdown Select User Labels from the tree Select Pipe Cut Labels Weld Report Include the Weld reports in BOM In Default Report.def file a sample reported is listed which user can use it as reference and customize and add more data as per requirement. See below sample Report. #----------------------------------------------------------------------------- # A sample weld report #----------------------------------------------------------------------------- REPORT = WELD include = IE_TYPE = CT_WELD COLUMN = 5:C:WELDID COLUMN = 10:R:SIZE COLUMN = 10::TYPE # the next two columns list the pipe/fitting connected by the weld. COLUMN = 30:W:left(EC_CLASS) COLUMN = 30:W:right(EC_CLASS) SORT = WELDID:N SEP = @ END Example: User can add report type in existing COMBI report and get the information. See below settings to see in BOM. Add values & report type in COMBI report. REPORT = combi WRITE = shp TEXT = @ TEXT = @ WRITE = fld TEXT = @ --------------------------------------------------------------------------------- TEXT = @ WELDID | SIZE | TYPE | CONNECTION-1 | CONNECTION-2 TEXT = @ --------------------------------------------------------------------------------- WRITE = WELD NODE = 60 END Save & close file. See Image below for Sample report. Note - H ere left(EC_CLASS) is always pipe as first connection if exists. Second EC_CLASS is second connection element. For more information of these attributes use, click here>>>> Spools List Report Include the Spools List reports in BOM User can add the following report type in report.def file and get the information. See below settings to see in BOM. Add the following report in report.def #----------------------------------------------------------------------------- # A sample Spools report #----------------------------------------------------------------------------- REPORT = SPOOLS INCLUDE = IE_FIELD=1 INCLUDE = IE_FIELD=0 COLUMN = 100:R: "SPOOL NUMBER " + PARTID + " = " + SPOOL_ID GROUP = SPOOL_ID SORT = SPOOL_ID:N SEP = @ NODE = 105 END Save & close file. Open Isometric Configuration -> Isometric Style -> Advanced -> Open Seed File Attach text node at proper place in the seed file Close the seed file; Generate Isometrics and Verify Result. Configure BOM Reports Include MARGIN between the Text in BOM A margin can be specified between text and the column borders. For instance with a column width of 30 and a margin of 2 only 26 mm will be usable for text. MARGIN can be specified outside a report. In that case every report will be initialized with that margin. When defined in a report the global margin will be overridden.The default value for margin is 1mm. #----------------------------------------------------------------------------- # A sample report that writes shop material to a report #----------------------------------------------------------------------------- MARGIN = 3 REPORT = SHP # this to include only shop material INCLUDE = IE_FIELD=0 EXCLUDE = IE_TYPE=CT_WELD COLUMN = 3: R : PARTID COLUMN = 19: R : QUANTITY COLUMN = 7: R : SIZE1 COLUMN = 7: R : SIZE2 COLUMN = 2: : COLUMN = 60: W : IE_DESCRIPT GROUP = PARTID SORT = PARTID:N SEP = @ SORTHEADERS = 1 TEXT = @ ---------------------------------------------------------- TEXT = @ Shop Materials TEXT = @ ---------------------------------------------------------- Write = END See BOM output shown for both without MARGIN and with MARGIN. Without MARGIN With MARGIN Include SPACING between the Text in BOM In Default Report.def file a sample reported is listed, which user can use it as reference and customize it as per requirement. See below sample Report. #----------------------------------------------------------------------------- # A sample report that writes shop material to a report #----------------------------------------------------------------------------- SPACING = 7 REPORT = SHP # this to include only shop material INCLUDE = IE_FIELD=0 EXCLUDE = IE_TYPE=CT_WELD COLUMN = 3: R : PARTID COLUMN = 19: R : QUANTITY COLUMN = 7: R : SIZE1 COLUMN = 7: R : SIZE2 COLUMN = 2: : COLUMN = 60: W : IE_DESCRIPT GROUP = PARTID SORT = PARTID:N SEP = @ SORTHEADERS = 1 TEXT = @ ---------------------------------------------------------- TEXT = @ Shop Materials TEXT = @ ---------------------------------------------------------- Write = END See BOM output shown for both without MARGIN and with MARGIN. Without SPACING value With SPACING value Separator (SEP) The separator is only used when the report is to be output as text. The SEP statement actually forces the report to be output as text. A report is no longer output as a formatted text files. A report line will never be wrapped. No matter what width is specified for a column, the full text is always output. Columns are concatenated separated by the SEP MAX-LINES Specifies the maximum number of lines available for the report. In case the report contain more lines the behavior is that the report continues with an offset to the right. In case MAX-LINES isn’t defined or is zero the report can have infinite length. This does implements multi column reports. Click here>>>> to check more information where this setting can be used. Also check >>>> for other example use of it. COLUMN COLUMN = 30: R : SIZE The COLUMN width field is now interpreted as a millimeter value instead of a character count. User may need to change their reports a bit. It will however make life much, much easier. Click here >>>> to check problem description article related to this. OpenPlant Isometrics Manager V8i (SELECTseries6) Version: 08.11.11.224 Refresh 2 Note the above versions are now using Millimeters instead of characters. Applicable to both AutoPLANT Modeler & OpenPlant Modeler Steps to Resolve OPEN { report.def } below is the old out of the box version settings. The following is altered for standard Out Of the Box Isometrics. Save file close and re-run the ISO to check results: NOTE : End user should open seed file and measure in MILLIMETERS according to their Custom BOM. This setup is specific to individual project basis and different settings may require based on various projects used. See results: For details click here>>>> . See Also User Can also See other wiki articles and its sub articles on configuring various types of reports in OpenPlant Isometrics Manager. Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

Viewing all articles
Browse latest Browse all 12277

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>