Wiki Page: How To Add & Write New Pipeline Size in OpenPlant PID

Applies To Products(s): OpenPlant PID Version(s): 08.11.10.XXX Environment Windows 7 (64 bit) Area Customization Subarea Size Original Author Jaya Tiwari, Bentley Product advantage Group Background In default setup there is only fixed sizes in Metric & Imperial Projects. In this wiki article we will see how user can configure their project to Add & Write New or Special Sizes in Size Field of Pipeline & Pipe Run. Steps To Accomplish Launch Bentley Class Editor. Open OpenPlant_PID. 01.07.ecschema.xml. Supplement with OpenPlant_PID_Supplemental_Imperial. 01.07.ecschema. Navigate to Pipe Run class. Switch to Size Property. Add Extend Type & Value Description Custom Attribute . Fill details as shown below. Navigate to Pipeline Class & switch to Design Size Property. Again, add Extend Type & Value Description Custom Attribute . Provide data as shown below. Save all Changes. Verify Result. Place Pipeline, check Extend type from drop down list of Pipeline. And user can also write a special size in Design Size field. See Also https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/26690/how-to-configure-openplant-pid-to-show-imperial-metric-sizes-in-the-same-project Comments & Corrections Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!