Applies To Bentley ProjectWise Integration Product(s): Project Administrator Version(s): 08.11.09.140 and greater Environment: N/A Area: ProjectWise Subarea: Integration Original Author: Brandon Moberg Bentley Product Advantage Group ERROR: Cannot find file Pwintutilsv8i.dll Problem Description The error "Cannot find file Pwintutilsv8i.dll" is received during ProjectWise Integration with an AutoPLANT Project in Project Administrator and or any other AutoPLANT Application that has been previously synced. Cause: The issue is due to the fact that the Pwintutilsv8i.dll file cannot be found to be read into memory and or registered. Solution: Browse to the C:\PROGRAM FILES(X86)\BENTLEY\PROJECTWISE\BIN\ folder and search for the PWINTUTILSV8I.DLL file. If the file is not in this folder a repair or reinstall is required. Add the C:\PROGRAM FILES(x86)\BENTLEY\PROJECTWISE\BIN\ folder pathing to the System Variable PATH section. Right Click on My Computer > Properties > Advanced System Settings > Advanced tab. Select the PATH variable in the System Variables section. Select the Edit button and add the C:\PROGRAM FILES(x86)\BENTLEY\PROJECTWISE\BIN path into the beginning of the PATH variable value line. Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧