Applies To Product(s): OpenPlant PID Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: N/A Subarea: N/A Original Author: Kestutis Mitkus, Bentley Product Advantage Group Overview Inside OpenPlant PID, user can create reports only for current dgn/dwg models, but there is a need to generate reports for whole project and use Data Manager's customized reports. Steps to resolve With Bentley Project administrator add OpenPlant PID Project's root and create new Project. Open Document Manager or Vision and in this Project create new OpenPlant PID drawing. Add required components and synchronize drawing with Plant Database. In Data Manager open required Report and verify results. As well you can import required Reports from other Projects Select create new report and in "Create New Report" dialog select "From Other Projects". Select from which Project and chose required Report. Open imported Report and verify results Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!