Applies To Product(s): OpenPlant PID Version(s): 08.11.09.XXX(SS5) | 08.11.11.309 (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Class Editor Subarea: Customization Original Author: Jaya Tiwari, Bentley Product Advantage Group Background Currently in OpenPlant PID, ISO project when Pressure Reducing Valve is placed on Pipeline & Synced from Drawing to Database. In Data Manager the information of line Tag is Not showing under Valve List Table. To achieve & reflect line Tag Information user need to perform below defined customization in Class Editor. Steps to Resolve Launch Class Editor. Browse the location : C:\ProgramData\Bentley\OpenPlantPID (SS6)\WorkSpace\Projects\OPPID_ISO\Dataset\schemas . Navigate to Relationship Class Mapping List . As shown in below image, Right click on Relationship Mapping row & Add Element . Fill data as highlighted below. Save all Changes. Verify Result. Launch OpenPlant PID. Open any ISO project dgn file. Create a Pipeline & Valve Pressure Reducing Valve on it. Synchronize from Drawing to Database. After successfully Synchronize, launch Data Manager. Navigate to Valve List table. Verify Line Tag information is present. See Also Comments or Corrections Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧