Quantcast
Channel: OpenPlant | AutoPLANT
Viewing all articles
Browse latest Browse all 12277

Wiki Page: Property is Read Only Error in OpenPlant Modeler

$
0
0
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.11.87(SS6) & Higher Environment: Windows 7/8.1/10 (64 bit) Area: Error/Logs/Message Subarea: Iso Sheet Generation Original Author: Jaya Tiwari, Bentley Product Advantage Group Overview While generating Iso Sheet from In_session project, in Pipeline Manager sometimes it shows a Error of Read Only Property. See below image. Steps To Resolve. Launch Bentley Class Editor . Open & Browse to OpenPlant_3D.01.07.ecschema Supplement OpenPlant_3D Schema with OpenPlant_3D_Supplemental_Isometrics_Isoextractor.01.07.ecschema. Navigate to the same property name as defined in Error log, refer below image here FOE_LINENUMBER. As highlighted below from Drop Down Arrow Change Read Only property to False . Save all Changes & Verify Result by Relaunching the OpenPlant Modeler & Generate Iso_Sheet. Still a Problem? If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround. Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!