Applies To Product(s): OpenPlant Orthographics Manager Version(s): 08.11.11.305 (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Component Tagging Subarea: Settings Original Author: Faisal Khan, BEPS-QA To Turn off Annotation for Hidden Components in OpenPlant Orthographics Manager’s Output Drawing Background If user wants to turn off tagging oh Hidden components in output, then it is possible for user to remove such characters by following below mentioned steps. Steps to Accomplish Launch OpenPlant Orthographics Manager and select a project Go to Drawing Generation --> Generate Select “demo-all” VAD file and Press “Generate Drawings” Output will be generated and annotation/tagging for Hidden components will also be shown in output Go to Settings --> Settings Settings dialog will pop up labeling “Project Settings [Project Name] ” Go to “Annotations --> Tag Numbers --> Common” Uncheck “Annotate all Components” box Save settings and close settings dialog Go to Drawing Generation --> Generate Select “demo-all” VAD file and Press “Generate Drawings” Output will be generated and No annotation/tagging for Hidden components See Also http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/30252.how-to-generate-output-drawing-in-openplant-orthographics-manager OpenPlant Orthographics Manager Help Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧