Quantcast
Channel: OpenPlant | AutoPLANT
Viewing all articles
Browse latest Browse all 12277

Forum Post: Release Announcement - Patch Update for AutoPLANT V8i (SELECTseries 7) Refresh

$
0
0
Hello, A new patch update – available as Prerequisites and Common Tools for AutoPLANT Applications v8i x64 Update 1 (Version 08.11.12.235) – has been released that can be installed on top of AutoPLANT V8i (SELECTseries 7) Refresh (Versions 08.11.12.226). This new patch provides support for OpenPlant PID SS6, allowing AutoPLANT SS7 Refresh users to use it.. Apart from that, this patch provides fixes for following issues: Message "Unable to load PWIntUtils..." appears at launch of OPIM in ProjectWise project with PW 08.11.11.590. Valves do not toggle at center AutoPLANT Piping and Equipment randomly losing data in the database and models when used with ProjectWise V8i SS4 08.11.09.590. AutoPipe command in AutoPLANT Modeler is not working when Advanced routing is disabled Runtime error when creating new annotation style Incorrect pipe length with reinforcement pad in Advanced routing Unhandled exception in component preferences when spec browser is loaded DataGridView Default Error Dialog when using From Component Line number does not change in component preference dialog LineNumber added via 'Update Component' dialog is not listed in the 'Component Preferences' area. Component Preferences option 'Data = From Settings' does not work during Advanced Routing. AP-OPIM: ISO file is not created for drawings having pulled pipes by In-Session scenario Pipe connected Equipment nozzle and nozzle information not appear in isometric Database Error' message appears at the opening document in SS4 project upgraded for SS7 Refresh DGN I&W drawings border's FILENAME shows .DWG file type instead of .DGN Random Check In fail, during files closing. Information message: Failed to switch active data source "DWG loses connection to ProjectWise, if dwg has page connectors and sync to db or save dwg” title block modify key in AutoPLANT enters demo mode with checked out license Document description disappears after its creation using AutoPLANT P&ID or Bentley OpenPlant Power PID application in ProjectWise Unhandled Exception occurs when opening Metric drawing in 'Drawing Access Mode/Configuration'. Advanced Routing. AP Modeler is not responding after applying UNDO during Advanced Routing. Advanced Routing. Different connection to Reducers during Advanced Routing. Isometric. Error message appears when running AutoPLANT Isometric. 'Automation error Invalid pointer' message appears when run 'OpenPlant Isometrics Manager V8i in AutoPLANT access mode' from desktop icon. Enter name of customization file to load error" message pop up when switch from piping drawing to equipment drawing. Advanced Routing. Wrong Port is highlighted after Undo action during advanced routing. This update can be uninstalled at any time to revert back to AutoPLANT V8i (SELECTseries 7) Refresh state without losing any information. Best Regards, Adnan Ulhaq Product Manager, AutoPLANT

Viewing all articles
Browse latest Browse all 12277

Trending Articles