Applies To Product(s): OpenPlant Isometrics Manager | AutoPLANT Modeler Version(s): 08.11.09.XXX Environment: Windows 7 (64 bit) Area: Settings/Attributes Subarea: Original Author: Abhijit Bute, Bentley Product Advantage Group Problem Description There could be project requirement connect component with one ends WFL connection and other ends are butt welded. But when we generate isometric for above assembly. Isometric may get crash.To avoid this crash refer following steps to resolve the problem. Steps to Resolve In Bentley Class Editor, open "OpenPlant_3D.01.04 schema". See Path Below for default storage. Ex. C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_METRIC\Config\OpenPLANT\schema Select "Weld Value Map" class. Go to Properties select "BUTT_WELD" Right click on ‘ ValueNameInAutoPLANT3D ’ and select Add element. Add value WFL. Remove WFL mapping from Wafer. Save the schema. Reopen AutoPLANT Modeler and generate isometric to review the result. Still a Problem? If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround. See Also Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧