Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.574 Environment: Windows 7 (64 bit) Area: Settings/Attributes Subarea: - Original Author: Abhijit Bute, Bentley Product Advantage Group Background When pipe is having rolled offset, Angle between Pipe and ISO axis is required in isometric to understand the dimension between vertical and horizontal axis. This should work in context with both OpenPlant Modeler-OpenPlant Isometric Manager & AutoPLANT Modeler-OpenPlant Isometrics Manager. However below has been illustrated in context with AutoPLANT Modeler & OpenPlant Isometrics Manager. Steps to Accomplish Go to current project location. Refer following example project path for default Metric project. C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_METRIC\Config\OpenPlant\Isometrics\styles\IFC Default Path for OpenPlant Modeler: C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\Projects\OPModeler_Metric\DataSet\Isometrics\Styles\IFC\Config Open "Style.xml" file in Notepad. Search for Change False>ShowAngels> to True >ShowAngels> Refer below Image Save the file and generate isometric to review the result. See image below. See Also Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧