OPIM is crashing due to four (4) Stop Signs reasonably close together. The Stop Signs are being used to separate spools enabling each spool of which there are several, to be on a separate sheets. The position of the stop signs has not changed for the last 3 months, and I have successfully run Isometrics with OPIM on the same pipeline. The only change to the problematic spool is that two (2) welds have changed from Shop Welds to Field Fit Welds today with 50mm additional length added (enabled option in the Schema). I had a similar problem last December 2015, but the latest version seemed to fix the problem until now. I really need the ability to place Stop Signs at practical positions normally at the Face of Flanges. If that is not possible, then placing Stop Signs to break up Iso's into practical Spools is useless. In the screenshot below you can see the Stop Signs in green (I changed the colour to make them more visible). The Spool is basically an "H" shape for fabrication, so I really need the Stop Signs where they are now placed. You can see below that where the first purple Isometric appears is where OPIM crashes. Line Number FG-51050-50-CA2B is the Spool in the image above that is causing the crash. Anyone have any ideas?
↧