Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.581 Environment: Windows 7 (64 bit) | Windows 8 Area: Component Subarea: Graphics - Olets-Welds-Placement Original Author: Rahul Kumar, Bentley Product Advantage Group Overview To Fix welds on Olets in OpenPlant Modeler. Problem Description In OpenPlant Modeler, on placement of olets with some end type preparation doesnot report welds on pipeline. Below steps help user to attain welds on a pipeline. Reason This has been occurred due to non-availability of end prep types on Joint class. See image below. User need to define all End prep types to avoid such problems. See below steps to resolve. Steps to Resolve In class Editor Open “OpenPlant_3D.01.06.ecschema” & Supplement it with below mentioned schema. “OpenPlant_3D_Supplemental_Modeling.01.06.ecschema”. Navigate to JOINT Class. Under Class Tab, Select Custom attribute “OpenPlant_Physical_JointType_Map” & Check joint type [8] . Right Click on End preparation2 and using “ Add Element ” option. See image below. Add all possible End preparation types. See image below. Save & close Schema. Launch OpenPlant Modeler, Place component & verify results. Note - For Existing Welds, user need to run Connectivity Checker to fix the case. Still a Problem? If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround. See Also Comments or Corrections? Bentley's Product advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!
↧