Actually, i don't know what exactly I should title this issue. In short, when trying to export components with different breaking criteria, error occurs. Here are steps to show the issue 1. place a piece of pipe with Linenumber L100 2. place an elbow connect to the pipe (with linenumber L100) 3. change pipe linenumber to other value, such as L200 4. bring up Import/Export module, and then export pcf (Import/Export --> Plant Exchange --> PCF --> Generate PCF) 5. Manual select the pipe and continue export with continue component set to 1 6. Get error message on Export Progress window says, "Error executing script for component: Class = AT_ELBOW_LR_90; CompID= AT_XXX_3" 7. go and open the generated pcf file, the continued elbow is missing Actuall similar error message show in OPIM export too, "Warning: ProjectObject ECInstance creation failed project object name: LINENUMBER, value L100:". Sometimes OPIM still output ISO properly, sometimes ISO generation failed. I was testing on out of box sample project with AutoPLANT version 8.11.12.226. Is possible to get a fix on this? Thank, Maggie
↧