Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.404 Environment: Windows 7 (64 bit) Area: Properties Subarea: Original Author: Harpreet Singh, Bentley Product Advantage Group Background While creating PIPELINE in OpenPlant Modeler we input number in the NUMBER property in Tag Information but that number property is not visible on the segments. NUMBER property shows null value under General Info in Element Info dialog. Steps to Accomplish Modification required in Schema Load OpenPlant_3D.01.04 schema in class editor and supplement with OpenPlant_3D_Supplemental_Modeling.01.04 schema. Go to NUMBER property of PIPE class and add Calculated EC property Specification custom attribute. Add the following EC expression in it. this.GetRelatedInstance("SEGMENT_HAS_PIPING_COMPONENT:1:PIPING_NETWORK_SEGMENT").GetRelatedInstance("PIPELINE_HAS_SEGMENT:1:PIPING_NETWORK_SYSTEM").NUMBER Save the changes. Verify Results Launch OpenPlant Modeler. Create New Pipeline and place a pipe segment. Check the Number Property under General Info category in Element Information dialog. Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧