Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.87 Environment: Windows 7 (64 bit) Area: Settings/Attributes Subarea: - Original Author: Michelle Saucier, Bentley Product Advantage Group Overview During isometrics generation in OpenPlant Isometrics Manager, below steps provides information on dimensioning of Gasket and Valve Separately. Problem Description While generating Isometric Sheet, User requires that the Gasket and Valve are dimensioned Separately. Steps to Resolve Launch OpenPlant Isometrics Manager. Under the Tools Tab> Configurations> Isometric Styles> uncheck (Combine Gasket with Flange). Check the box ( Dimension Gasket ). Save Changes and close Configuration Manager and regenerate Iso Sheet. See Also Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧