Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.470 & Above Environment: Windows 7 64 bit & Others Area: Settings/Attributes Subarea: Original Author: Abhijit Bute, Product Advantage Group Background As per project requirement some user wanted to have some reserved weld ids in AutoPLANT Modeler. And expect that Isometric should retain those assigned weld ids. Below illustrative steps helps user to achieve desired result. Steps to Accomplish Open Project Administrator and click on “Create/Modify” option. This will launch Isometrics “Isometric Configuration” dialog box. Select correct style and click on User Labels. Edit Weld Labels as per below image Create new user label and give name ‘Weld Label2’ Edit As per below Image Click save. Generate isometric to review the result. See Also Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU
↧