Wiki Page: “Component Not Valid Due to Invalid Ports” Error While Checking Out Components

$
0
0
Applies To Product(s): OpenPlant ModelServer Version(s): 08.11.12.23 Environment: Windows 7/8 (64 bit) Area: Operations Subarea: Original Author: Harpreet Singh, Bentley Product Advantage Group Problem Description While checking out pipeline which has LAP_JOINT_FLANGE below error appears in the checkout dialog, however components are checked out correctly. This error appears when you are using a combination of OpenPlant Modeler SS5 (08.11.09.568) workspace with SS6 version 08.11.11.87. Steps to Resolve Launch class editor. Load OpenPlant_3D_Supplemental_Information_3DComponent.01.06.ecschema.xml schema. Go to LAP_JOINT_FLANGE class. Change the number of ports to 0 in Component Ports Information custom attribute as highlighted below. Save the changes in the schema and check in back to ProjectWise. Check out the same pipeline which has lap joint flange. There will be no error message this time. Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!