Applies To Product(s): AutoPLANT Piping Version(s): 08.11.09.140 Environment: Windows XP x32bit Area: General Subarea: Original Author: Artiom Jakubovic, Bentley Technical Support Group Problem Description This issue appeared on Windows XP x32 bit PC with AutoPlant 2004 after installing AutoCAD 2012 + AutoPlant SS4 08.11.09.140. Below message was shown while trying to launch SS4 Document Manager DocMgr Run-time error ‘372’: Failed to load control ‘TagProperties’ from APTagTree,ocx. Your version of APTagTree.ocx may be outdated. Make sure you are using the version of the control that was provided with your application. While trying to launch AutoPlant SS4 using Plant Design for AutoCAD 2012 shortcut and loading Piping from AutoPlant 3D below messages are shown. Same messages are shown while trying to place any component in Piping model. AutoPLANT Message Compile Error... Script is too large to be compiled Line: 22659 Column: 47 Script error P5Y50503: Error loading script File C:\\Program Files\\Bentley\\Plant V8i\\Modules\\Base\\PIPING\\util\\ports.ebs . Steps to Resolve Copy DLL from attached zip BasicScript SS4.zip to C:\WINDOWS\system32. Just in case, leave existing files as back up copy. Now open CMD as administrator and re-register vsflex8l.ocx using this line: regsvr32 C:\windows\system32\vsflex8l.ocx
↧