Wiki Page: How to Change the Version of AutoCAD Used on Startup. AutoPLANT AT.ini

$
0
0
Applies To Product(s): AutoPLANT Modeler Version(s): N/A Environment: Windows 7 32 bit, Windows 7 64 bit, Windows XP 32 bit Area: N/A Subarea: N/A Original Author: Joey Bertone, Bentley Technical Support Group How to change the version of AutoCAD used on startup Both Document Manager and Vision use the data in AT.ini to determine the version of AutoCAD and what profile is used to open AutoPLANT. By default when AutoPLANT installed the newest version of AutoCAD available on each computer; because of this the AT.ini can point to a version or variant (LT, MEP, Map 3D, etc…) of AutoCAD that is not supported. AT.ini file location Windows 7 C:\ProgramData\Bentley\Plant V8i\CFG Windows XP C:\Documents and Settings\All Users\Application Data\Bentley\Plant XM\CFG Because of its location at.ini is not project specific it is workstation specific. Changing the AutoCAD version Open the AT.ini Find the [PIPING] section Locate the CADAPP section Change the CADAPP path to reflect the version of AutoCAD that is supported. Example: Change from: CADAPP=C:\Program Files\Autodesk\AutoCAD 2013\acad.exe Change to CADAPP=C:\Program Files\Autodesk\AutoCAD 2012 - English\acad.exe Locate AcadCmdLine Change the AcadCmdLine path to reflect the version of the AutoCAD profile in use. This step may not be needed. Example: Change from: AcadCmdLine=/p "C:\ProgramData\Bentley\Plant V8i\AutoPLANT_SS3_PDW811ACAD_ B001 _409.arg" /b loadpiping Change from: AcadCmdLine=/p "C:\ProgramData\Bentley\Plant V8i\AutoPLANT_SS3_PDW811ACAD_ A001 _409.arg" /b loadpiping Change each section that have CADAPP and AcadCmdLine and save the file. Once changed the save the file and opened files from document manager and vision will open the requried AutoCAD. Other AutoPLANT Modeler profile versions AutoCAD 2012 AutoPLANT_Modeler811ACAD_B001_409.arg AutoCAD 2014 AutoPLANT_Modeler811ACAD_D001_409.arg AutoCAD 2015 AutoPLANT_Modeler811ACAD_E001_409.arg See Also Product TechNotes and FAQs External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

Viewing all articles
Browse latest Browse all 12277

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>