Quantcast
Channel: OpenPlant | AutoPLANT
Browsing all 12277 articles
Browse latest View live
↧

Forum Post: RE: OPM SS6 - Default spec attributes

Hi Rahul, SR 7000573830 has been raised for this matter. Tuan

View Article


Forum Post: RE: WIKI entries - Path to classes

Hello Tuan, Thanks for your suggestion here. We are modifying the wikis based on user suggestions and been implementing the same. We will modify this content as well with the classes to navigate....

View Article


Forum Post: RE: WIKI entries - Path to classes

Hi Rahul, I indeed forgot to look for a search option. Thanks for the pointing that out. Best regards, Tuan

View Article

Forum Post: OPIM SS6 - mapping for custom OPM pipeline property

Hi, Say I have a custom property for PIPELINE in OPM, named PID_NO. Is there away to map that to OPIM? Essentially what I'm looking for is some process similar to this But for pipelines, not...

View Article

Forum Post: OPIM SS6 - Debug.txt file

Hi, With other applications (AECOSim, Microstation, OPM etc.), using the command line -debug will produce a snapshot of the configuration variables processing and their values during startup. Is there...

View Article


Forum Post: RE: OPIM SS6 - How to show full line number in continuation label...

Hello Tuan, I think you have asked same question in this thread and one of my colleagues have commented for you: Best Regards, Kestutis M.

View Article

Forum Post: RE: OPIM SS6 - Debug.txt file

Hi Tuan, You can use below option (View MS Config) to see all the variables along with their values: This will generate a txt file with all the configuration variables and their values as shown below....

View Article

Forum Post: RE: OPIM SS6 - mapping for custom OPM pipeline property

Hello Tuan, You have found correct wiki Instead of Pipe Reducer do same steps for Pipe Class. And then after adding additional user label in OPIM you will have this TAG in your generated Iso. Please...

View Article


Forum Post: RE: OPIM SS6 - Assign P&ID drawing number for pipeline

Hello Tuan, I think you are asking same question in this thread: communities.bentley.com/.../393024 Regards, Kestutis M.

View Article


Forum Post: RE: OPIM SS6 - mapping for custom OPM pipeline property

Hi Kestutis, What you suggested is for PIPE component, which is not what I'm after. I would like to map a custom property of a PIPELINE itself, not a component.

View Article

Forum Post: RE: OPIM SS6 - Debug.txt file

Thanks for this Harpreet. It is handy. However, can I get something that it's similar to msdebug.txt in terms content? The msdebug.txt shows a detailed level of what and how config files (line by line)...

View Article

Forum Post: OPIM SS6 - Show all mating flange labels

Hi, It seems when there's a matting flange connection, only 1 flange label is shown. Can I turn on the other flange's label as well? For example, in the snapshot below, I would like 2 F2 labels, 1 for...

View Article

Forum Post: RE: OPIM SS6 - mapping for custom OPM pipeline property

OpenPlant Isometrics Manager, shows the graphical component data in drawings. Since Pipeline is non-graphical so you can't see pipeline attributes in isometric drawings. However, you can define the...

View Article


Forum Post: RE: OPIM SS6 - mapping for custom OPM pipeline property

Thanks Harpreet. I don't think I can make that work for what I'm trying to do though. Take a pipeline's "Design Pressure" property as example. That property is per pipeline, not per component. And...

View Article

Forum Post: RE: OPIM SS6 - Debug.txt file

That is a MicroStation feature and you can do the same with OpenPlantIsoExtractor.exe but that's only on a project level and not the style level. You will have to create a shortcut and add =debug to...

View Article


Forum Post: RE: OPIM SS6 - Show all mating flange labels

Hi Tuan, Currently this is not possible. We will need to log an enhancement request for this, please create SR for the same. Regards, Harpreet

View Article

Forum Post: RE: OPIM SS6 - Debug.txt file

Thanks Harpreet. Thought I had tried that in the past and didn't work. But you're right. The full cmd switches are available for OpenPlantIsoExtractor.exe. Thank you very much again. Best regards, Tuan

View Article


Forum Post: RE: OPIM SS6 - Show all mating flange labels

Hi Harpreet, SR 7000574047 has been raised. Best regards, Tuan

View Article

Wiki Page: Understanding Component Preferences In AutoPLANT [TN]

Applies To Product(s): AutoPLANT Plant Design Version(s): XM Edition Environment: N/A Area: N/A Subarea: N/A Original Author: Jesse Wolfe, Bentley Product Advantage Group Overview Many new features...

View Article

Forum Post: JOINING PIPES AT AN ANGLE WITHOUT ANGLE at a certain angle (let's...

I want to join two piece of pipe, that are under cerain angle to each other (let's say 15 degrees) but I can't use elbows (I must specyfy just pipe). Summary: I want to have possibility to join pipes...

View Article
Browsing all 12277 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>