Applies To Product(s): OpenPlant Reporting Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Grid Report Subarea: Original Author: Deepak Singh, Bentley...
View ArticleWiki Page: How to Include XYZ Coordinates in Reports for Piping Components
Applies To Product(s): OpenPlant Reporting Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: DGN Reporting Subarea: Grid Report Original Author: Harpreet...
View ArticleForum Post: RE: OPPID, Custom Border with new properties
Hi Stephen, You have added properties on PID_DOCUMENT class? and you can't see them in Drawing Settings dialog, is that the issue? Please confirm. Regards, Harpreet
View ArticleForum Post: RE: OPM SS6 - component with BSP threads
Hello Tuan, Sorry, I was on vacation for two weeks, hence not able to respond. Will update you shortly. -Regards | Rahul Kumar
View ArticleForum Post: RE: OPM SS6 - Threaded tap port
Hello Tuan, Sorry, I was on vacation for two weeks, hence not able to respond. We will share the Enhancement number soon. -Regards | Rahul Kumar
View ArticleForum Post: OPM SS6 - Connecting components of different rating
Hi, I see it's possible to do it in Autoplant as per the wiki below: Can the same thing be done in OPM?
View ArticleForum Post: RE: OPM SS6 - Connecting components of different rating
Hi Tuan, Yes, it can be done in OpenPlant Modeler as well. You just need to modify the variable given in Project PCF file i.e. OPM_MATCH_PROPERTY_MAP_RATING Please refer below wiki article for this:...
View ArticleWiki Page: To Customize Spool Labels Based on CUTID and Other Attributes
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX (SS5) Environment: Windows 7 ( 64 bit) Area: Settings/Attributes Subarea: - Original Author: Rahul Kumar, Bentley Product...
View ArticleWiki Page: How to Change Page Connector Annotation Class
Applies To Product(s): OpenPlant PowerPID Version(s): 08.11.10.202 Environment: N/A Area: Tags Subarea: Original Author: Justinas Lipnickas, Bentley Product Advantage Group Overview By default,...
View ArticleForum Post: RE: OPPID, Custom Border with new properties
Harpreet, I followed the procedure but at step 22, I can’t find the "Property Priority" custom attribute. Schema structure (1.07) seems to be changed in SS6 release. I don’t see DOCUMENT_PID but only...
View ArticleWiki Page: Error "No default report template is defined for this report"...
Applies To Product(s): OpenPlant Reporting Version(s): 08.11.09.XXX (SS5) & 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: DGN Reporting Subarea: Original Author: Harpreet Singh,...
View ArticleForum Post: RE: OPPID, Custom Border with new properties
Hello SH, The OpenPlant_ProjectProperties schema was used in the past and can still be used today, however, I recommend you add the properties to the OpenPlant PID schema. Add them under the...
View ArticleWiki Page: OpenPlant Reporting
OpenPlant Reporting OpenPlant Reporting is an OpenPlant application which provides an interface to generate reports from either the OpenPlant Modeler application, or as a Standalone application...
View ArticleWiki Page: How to Add/Remove HVAC Component Classes in Grid Report
Applies To Product(s): OpenPlant Reporting Version(s): 08.11.09.XXX (SS5) & 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: DGN Reporting Subarea: HVAC Original Author: Harpreet...
View ArticleForum Post: RE: OPM SS6 - Connecting components of different rating
Hi Harpreet, Thanks for this. Doing that essentially make all pipe sizes of 1 rating (saying 300lb) compatible with another rating (say 600lb) which is not entirely correct. For example, between 300lb...
View ArticleForum Post: RE: OPPID, Custom Border with new properties
Thanks Tony, That was the part that was missing (PID_DOCUMENT class). Works fine now. For the priority, I saw the field under the property and set it there. Thanks, SH
View ArticleForum Post: OPPID, Project configuration folder
Hi, Using OPPID SS6 Trying to locate project configuration folder, the one we can choose when opening a file: I'd like to have it on a file server so configuration or schema files that are updated...
View ArticleForum Post: OPPID, Pipeline custom annotation
Hi, Using OPPID SS6 Trying to create and/or edit a pipeline custom annotation. Tried with the following procedure but seems that schema structure has been changed....
View ArticleForum Post: RE: OPPID, Pipeline custom annotation
Hi Stephane, The procedure has not changed. Are you facing any issue in a particular step? Regards, Harpreet
View ArticleForum Post: RE: OPPID, Project configuration folder
Hi Stephane, You can copy the workspace on network location and access the projects from that workspace. You just need to modify msdir.cfg file (located in C:\Program Files (x86)\Bentley\OpenPlantPID...
View Article