Quantcast
Channel: OpenPlant | AutoPLANT
Browsing all 12277 articles
Browse latest View live

Forum Post: RE: trying to create a mixed metric isometric

we are using mixed metric. for this project

View Article


Wiki Page: Modifying Symbols

Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: - Original Author: Keith Couvillion, Bentley Technical...

View Article


Wiki Page: How To Modify TIE-IN Point Symbol

Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.404 & above Environment: Windows 7 64 bit & Others Area: Settings/Attributes Subarea: - Original Author: Rahul Kumar,...

View Article

Wiki Page: How to present AutoPLANT Nozzle Rating and Facing Information in...

Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 32/64-bit Area: Settings/Attributes Subarea: Original Author: Abhijit Bute, Bentley Technical Support...

View Article

Forum Post: RE: trying to create a mixed metric isometric

Hello Kevin, I tried to reproduce your issue on my side, but i am not able to reproduce it on my side. As per error message it seems that problem with '***.mld' file. Could you please attached mld...

View Article


Forum Post: RE: Bulk BOM Take-off report

Hello Sean, when generate isometric in OpenPlant Isometric Manager. BOM reports are generated on following project path Below attached image for default Metric project path. Hope this helps you....

View Article

Wiki Page: How to Automatically Annotate Nozzle Tag After Placement

Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX Environment: Windows 7 (64 bit) Area: Customization Subarea: Original Author: Harpreet Singh, Bentley Product Advantage Group Background...

View Article

Wiki Page: Default Annotation of Pipe Run with Pipeline Tag

Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX Environment: Windows 7 (64 bit) Area: Customization Subarea: Original Author: Harpreet Singh, Bentley Product Advantage Group Description...

View Article


Wiki Page: OpenPlant Product Group Compatibility

Here compatibility across different release versions of OpenPlant Product Group with Operating Systems, ProjectWise and various Database types is presented. The compatibility matrixes are available in...

View Article


Forum Post: RE: AutoPLANT SS7r on AutoCAD 2016??

Dinesh, do you know when the new AutoPLANT SS8 will be released? Regards, Scott

View Article

Forum Post: How can I turn off the Advanced Routing on SS7?

How can I turn off the Advanced Routing on SS7? The help file states I should be able to type in ADVANCEROUTING to toggle it on and off but Autocad doesn't recognize that as a command. I believe the...

View Article

Forum Post: RE: AutoPLANT Spool ID's in OPIM Isometric Output

Thanks, that did the trick. Completely forgot all about the S flag. Cheers.

View Article

Forum Post: RE: trying to create a mixed metric isometric

how do i send you my ***.mld file?

View Article


Forum Post: RE: How can I turn off the Advanced Routing on SS7?

Go to C:\ProgramData\Bentley\Plant V8i\CFG find at.ini In the at.ini file search for [Piping] Section and change the following line from 1 to 0: [PIPING] ADVANCEDROUTING=0 Advanced Pipe Routing will...

View Article

Forum Post: RE: AutoPLANT SS7r on AutoCAD 2016??

Hello Scott, The release is planned in Mid April 2016. Regards Dinesh

View Article


Wiki Page: AP2OP Mapping Methodology – Generating Isometrics in OPIM via...

Applies To Product(s): AutoPLANT Modeler Version(s): 08.11.10.182 Environment: Windows 7 (64 bit) Area: Subarea: N/A Original Author: Jake Campbell, Bentley Product Advantage Group Overview In order to...

View Article

Forum Post: RE: Separating BOM Groups

Hi Frank, That worked, thank you very much. One small thing though, blind flanges are being put in another section. I have tried a few things to try to fix it myself but I have been unsuccessful. It...

View Article


Forum Post: RE: Separating BOM Groups

Hi Sean, By default OPIM assigns part ID's to shop items first, field items second. The blind flange is seen as field as it is a loose component. If you don't need the distinction between shop and...

View Article

Forum Post: RE: Separating BOM Groups

Hello Sean, You can also refer below wiki link for various BOM report types: -Regards | Rahul Kumar

View Article

Forum Post: RE: Separating BOM Groups

Thank you very much Frank, that has worked out perfectly. Thank you too Rahul for the link.

View Article
Browsing all 12277 articles
Browse latest View live