Forum Post: RE: trying to create a mixed metric isometric
we are using mixed metric. for this project
View ArticleWiki Page: Modifying Symbols
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: - Original Author: Keith Couvillion, Bentley Technical...
View ArticleWiki Page: How To Modify TIE-IN Point Symbol
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.404 & above Environment: Windows 7 64 bit & Others Area: Settings/Attributes Subarea: - Original Author: Rahul Kumar,...
View ArticleWiki Page: How to present AutoPLANT Nozzle Rating and Facing Information in...
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 32/64-bit Area: Settings/Attributes Subarea: Original Author: Abhijit Bute, Bentley Technical Support...
View ArticleForum Post: RE: trying to create a mixed metric isometric
Hello Kevin, I tried to reproduce your issue on my side, but i am not able to reproduce it on my side. As per error message it seems that problem with '***.mld' file. Could you please attached mld...
View ArticleForum Post: RE: Bulk BOM Take-off report
Hello Sean, when generate isometric in OpenPlant Isometric Manager. BOM reports are generated on following project path Below attached image for default Metric project path. Hope this helps you....
View ArticleWiki Page: How to Automatically Annotate Nozzle Tag After Placement
Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX Environment: Windows 7 (64 bit) Area: Customization Subarea: Original Author: Harpreet Singh, Bentley Product Advantage Group Background...
View ArticleWiki Page: Default Annotation of Pipe Run with Pipeline Tag
Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX Environment: Windows 7 (64 bit) Area: Customization Subarea: Original Author: Harpreet Singh, Bentley Product Advantage Group Description...
View ArticleWiki Page: OpenPlant Product Group Compatibility
Here compatibility across different release versions of OpenPlant Product Group with Operating Systems, ProjectWise and various Database types is presented. The compatibility matrixes are available in...
View ArticleForum Post: RE: AutoPLANT SS7r on AutoCAD 2016??
Dinesh, do you know when the new AutoPLANT SS8 will be released? Regards, Scott
View ArticleForum Post: How can I turn off the Advanced Routing on SS7?
How can I turn off the Advanced Routing on SS7? The help file states I should be able to type in ADVANCEROUTING to toggle it on and off but Autocad doesn't recognize that as a command. I believe the...
View ArticleForum Post: RE: AutoPLANT Spool ID's in OPIM Isometric Output
Thanks, that did the trick. Completely forgot all about the S flag. Cheers.
View ArticleForum Post: RE: trying to create a mixed metric isometric
how do i send you my ***.mld file?
View ArticleForum Post: RE: How can I turn off the Advanced Routing on SS7?
Go to C:\ProgramData\Bentley\Plant V8i\CFG find at.ini In the at.ini file search for [Piping] Section and change the following line from 1 to 0: [PIPING] ADVANCEDROUTING=0 Advanced Pipe Routing will...
View ArticleForum Post: RE: AutoPLANT SS7r on AutoCAD 2016??
Hello Scott, The release is planned in Mid April 2016. Regards Dinesh
View ArticleWiki Page: AP2OP Mapping Methodology – Generating Isometrics in OPIM via...
Applies To Product(s): AutoPLANT Modeler Version(s): 08.11.10.182 Environment: Windows 7 (64 bit) Area: Subarea: N/A Original Author: Jake Campbell, Bentley Product Advantage Group Overview In order to...
View ArticleForum Post: RE: Separating BOM Groups
Hi Frank, That worked, thank you very much. One small thing though, blind flanges are being put in another section. I have tried a few things to try to fix it myself but I have been unsuccessful. It...
View ArticleForum Post: RE: Separating BOM Groups
Hi Sean, By default OPIM assigns part ID's to shop items first, field items second. The blind flange is seen as field as it is a loose component. If you don't need the distinction between shop and...
View ArticleForum Post: RE: Separating BOM Groups
Hello Sean, You can also refer below wiki link for various BOM report types: -Regards | Rahul Kumar
View ArticleForum Post: RE: Separating BOM Groups
Thank you very much Frank, that has worked out perfectly. Thank you too Rahul for the link.