Forum Post: RE: OPM SS6 - Place bolt and gasket at open flange
Hello Tuan, There could be many things included to place it on an open end. Bolt length/Gasket thickness to be predefined while placement. I would suggest you to log an SR for enhancement. HTH -Regards...
View ArticleWiki Page: OPPID - Ss6 What is New
What is New in OpenPlant PID V8 i (SELECTseries 6) V08.11.11 What’s New? The OpenPlant PID V8 i (SELECTseries 6) release is the latest release of our newest Intelligent P&ID Solution. OpenPlant PID...
View ArticleWiki Page: OPPID - Ss6 Requirements
OpenPlant PID V8 i (SELECTseries 6) Requirements Processor Memory Hard disk Input device Output device Video Graphics card Operating system Optional Integrations Processor Intel ® or AMD ® processor...
View ArticleWiki Page: OPPID - Ss6 Known Issues
Known Issues in OpenPlant PID V8 i (SELECTseries 6) V08.11.11 Known Issues of OpenPlant PID V8 i (SELECTseries 6) Drafting: Whenever InRun Spec Validation dialog is opened, you must Apply (green check...
View ArticleForum Post: OpenPlant Isometric Manager does not update distances to supports
Hello, We are finding that after some revisions to our models when we regenerate an isometric the distances to supports are not correct. I haven't been able to clearly identify why some do and others...
View ArticleForum Post: RE: OpenPlant Isometric Manager does not update distances to...
Hi, Can you attach the images again? Also confirm the product you are using OpenPlant Isometrics Manager with? Is it AutoPlant Modeler or OpenPlant Modeler? What are the versions you are using?...
View ArticleWiki Page: To Add Pipe Allowances as Field Fit Length in Grid Report
Applies To Product(s): OpenPlant Reporting Version(s): 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Piping Component Subarea: Weld Reports Original Author: Rahul Kumar, Bentley...
View ArticleWiki Page: OpenPlant Reporting
OpenPlant Reporting OpenPlant Reporting is an OpenPlant application which provides an interface to generate reports from either the OpenPlant Modeler application, or as a Standalone application...
View ArticleWiki Page: How to place Pipe Nozzel tag and continuation on Iso.
Because the Pipe Nozzle does nor behave the same as an Equipment nozzle, it does not show the connection. Please make a new user label with the following settings. Name = Pipe Nozzle Include =...
View ArticleWiki Page: How to Change Pipeline Color and Line Weight
Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Customization Subarea: Original Author: Harpreet Singh, Bentley...
View ArticleForum Post: OPPID, Plant Component Edit
Hi, Using OPPID SS6 In te Drawing settings window, Plant tab. Edit button stays greyed out, can't edit existing items. SH
View ArticleForum Post: OPPID, Valve replacement, Symbol
Hi, Using OPPID SS6 When using Replace menu to replace a valve type. Most of the valve are related to the same symbol. Gate Valve: HVALVE_GATE_OPEN SH
View ArticleForum Post: OPPID, Parser reguler expression and slash character
Hi, Using OPPID SS6 When using the slash / symbol in properties like Sizes or Services. If these properties are part of the name object (ex.: Pipeline) the Parser regular expression get wrong value....
View ArticleForum Post: RE: OpenPlant Isometric Manager does not update distances to...
We are using OPIM with AutoPlant Modeler Version 8.11.11.135
View ArticleForum Post: RE: OPPID, Valve replacement, Symbol
Hi Stephane, You can change the cell name in Schematics CAD custom attribute in class editor for that particular class. For example, GATE_VALVE_CLOSED class shows cell name "HVALVE_GATE_OPEN" as shown...
View ArticleForum Post: RE: OPPID, Valve replacement, Symbol
Thanks for the information but I would have expected that these settings would already be done. There are multiple valves that are using the wrong symbol. SH
View ArticleForum Post: ATDB0801: Unable to update drawing name in drawing's data dictionary
AutoPLANT Modeler SS6 08.11.11.135 Add customer XREF to existing ProjectWise model file Save changes to ProjectWise and the error is displayed. Microsoft Office 2010 Windows 7 Professional SP 1 This...
View ArticleForum Post: Open AutoPlant drawing from ProjectWise does not return to last...
ProjectWise V8i 08.11.11.590 AutoPLANT Modeler SS6 08.11.11.135 AutoCAD 2014 SP1 When opening a drawing or attaching x-ref from ProjectWise the open file dialog does not return to the last used folder...
View Article