Forum Post: RE: Custom piping Item
Hi Marus, Thanks for your quick reply, maybe i should have made it clearer but we're using AutoPlant here in our office and not OpenPlant. i don't think your solution will work for me. thanks anyway!...
View ArticleForum Post: RE: Custom piping Item
oh sry i had read as tag "OpenPlant Modeler", my eyes would be not the best :D
View ArticleForum Post: RE: OPIM Split Isometric over several sheets (AutoPLANT SS7 Refresh)
Hello Steve, I would suggest you to please log a Service Request for this query along with relevant details & requirements, so that we should be able to log it as an enhancement item. -Regards |...
View ArticleComment on How to configure OpenPlant to allow flange connection with...
What does the ".PAIR" do at the end of Match Property? In our testing we saw that just enabling the OPM_MATCH_PROPERTY_MAP_FACING and adding the necessary facing values allowed us to connect the...
View ArticleWiki Page: How to configure OpenPlant to allow flange connection with...
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Component Subarea: Original Author: Harpreet Singh, Bentley Product Advantage Group Background...
View ArticleComment on How to configure OpenPlant to allow flange connection with...
Thanks Ben, I just tested myself and found that this schema change is not required. This wiki was created w.r.t old version and may be this is not required anymore. I have modified the steps now....
View ArticleWiki Page: AutoPLANT AT.ini
Applies To Product(s): AutoPLANT Modeler Version(s): N/A Environment: Windows 7 32 bit, Windows 7 64 bit, Windows XP 32 bit Area: N/A Subarea: N/A Original Author: Joey Bertone, Bentley Technical...
View ArticleForum Post: RELATIONSHIP MANAGER. Error upgrading to 8.9 Autoplant format
Hi, I having problem trying to package or export some P&I diagrams to another project. The complete text is: ------------------------------------------ Upgrading component xData to the 8.9...
View ArticleForum Post: RE: RELATIONSHIP MANAGER. Error upgrading to 8.9 Autoplant format
Hi, Are you facing this problem with some specific drawings? you can check one forum link below where similar discussion done. Please update on this. You may expect some expert replies on this....
View ArticleForum Post: Crystal Reports
Which version of Crystal Reports would I need to use with AutoPLANT SS7 Ver. 8.11.12.226 for creating or amending Reports?
View ArticleForum Post: RE: How i can give Directional Support Guides attributinformation...
Hi all, i had test it on version .447 and .564 and only on .564 the directional support guides works right. regards, Markus
View ArticleForum Post: RE: How i can give Directional Support Guides attributinformation...
Thanks to Verify it Markus, Please keep posting all your concern related to plant product. we will be glad to assist you. -Regards | Rahul Kumar
View ArticleForum Post: Open Plant Class Steam trap ?
Hi all, i wanna integrate steam traps in my pipe class, but the schemas only have a Steam_trap class without any graphics information. Can i integrate steam traps myself, like i copy the left...
View ArticleForum Post: RE: Open Plant Class Steam trap ?
Hello Markus, Yes it has not been included in default OpenPlant Modeler. I would suggest you to log a Service Request with relevant details to take this up with development team. In schema one way to...
View ArticleForum Post: RE: Open Plant Class Steam trap ?
Ok, then i try first to integrate it mysafe with i check other class for reference and if that not work i will log a Service Request. If i get a solution myself i will post it here.
View ArticleForum Post: DGN Report within OPM
Hello there, I am trying to create DGN report template according to the local standard. as the following steps: 1, Edit Report 2, Edit Template 3, Query Sets: all desired properties checked. 4, after...
View ArticleForum Post: RE: DGN Report within OPM
Hi Joe, Did you add the tag sets and tags to work for the DGN templates? I am not sure if DGN templates work for OpenPlant Modeler like it works for OpenPlant PID. 2nd Question: You want the total...
View ArticleForum Post: RE: DGN Report within OPM
Mr. Harpreet, Have no idea of tag sets or tags for DGN templates. So, it's not the text %Property you're talking about?! For Q2, actually I want the total length of same pipes and total number of same...
View ArticleWiki Page: OPSE: Project Dashboard
OpenPlant Support Engineering Project Dashboard related issues, tips, workflows, and other information will be shared in this section.
View ArticleForum Post: RE: Open Plant Class Steam trap ?
ok now i can load my steam traps out of my pipe spec as custom component. The only problem is OPM has no button for steam traps in the task panel. Can you help me how i can add a button in the task...
View Article