Forum Post: RE: Upgrade project from XM to V8i
Hello Lance, Please create Service Request for our AutoPLANT Team and one of our analysts will try to help you in this situation. I think we will ask you to share for us all this data for testing. Best...
View ArticleForum Post: RE: Continuation Missing On Isometrics (OpenPlant)
Hello Sean, Could you please also check following settings in preference settings set continuing components set to 1. if it set to 0 then it will not show continuation. Hope this help. Looking forward...
View ArticleForum Post: RE: OpenPlant linenumbers and valve numbers from database
Hello Mathys, Thank you for choosing our products and glad to hear, that your are trying to learn so much. Please Inform us about which product and their version numbers exactly are you talking here?...
View ArticleForum Post: RE: Continuation Missing On Isometrics (OpenPlant)
Hi, How do I access these settings again? Kind Regards, Sean
View ArticleForum Post: RE: Continuation Missing On Isometrics (OpenPlant)
Hello Sean, You will get this setting by following steps. 1. Import/Export>Create Iso Via OPIM 2. Once you select component for Iso generation either Manual or Advance selection. 3. Preferences...
View ArticleForum Post: RE: Continuation Missing On Isometrics (OpenPlant)
Thank you, this is working now! Can I also add that the "Use Stop Sign" box should be ticked. This also wasn't working for me previously but is now. Thanks again.
View ArticleForum Post: RE: Continuation Missing On Isometrics (OpenPlant)
Hello Sean, Thanks for your reply. If you have assigned stop sign in model, then you can check on stop sign option. Isometric will split on the basis of stop sign. Regards, Abhijit Bute
View ArticleForum Post: RE: OpenPlant linenumbers and valve numbers from database
Sorry, left that bit out. OpenPlant 3D Modeler V8i Ver 08.11.11.238
View ArticleForum Post: AP-OPIM - shop field material setting in BOM
Using IE_FIELD to split components in BOM report does not always work. Please see picture below, PIPE item 6 (SHOP_FLD=1 in AutoPLANT) for some reason fall in FIELD MATERIAL section. I tried to use...
View ArticleForum Post: RE: OpenPlant linenumbers and valve numbers from database
Hello Mathys, Thanks for writing. Value from database can be mapped using External db query. See fundamental as well as sample wiki for your reference. However for importing Pipeline inside OpenPlant...
View ArticleForum Post: RE: AP-OPIM - shop field material setting in BOM
Hello Maggie, Thanks for the question. This question required detail investigation. Could you please raise service request for this question, also provide us pxf file and style folder for further...
View ArticleForum Post: Spec Break orientation OPPID
Hello, I have a problem with my spec break component, i want to be able to chose the orientation of the spec break when i insert into pipe. Thank you
View ArticleForum Post: Error 2760 installing Prerequisite
Hello During the installation of prerequisitse apr64081113211en.exe at the first step I receive the CONNECTION Client error (error-2760). If I try to install apm64081113211en.exe. I get the...
View ArticleForum Post: RE: Spec Break orientation OPPID
Hello Nuno, Can you please provide some screenshot of your concern. However, you can also refer similar wiki link on spec break customization. HTH Regards | Jaya
View ArticleForum Post: RE: Spec Break orientation OPPID
i have already my spec break component, i want just to have the option when i insert into pipeline to chose orientation, if its vertical pipeline left or right.If pipeline horizontal up or down. thank...
View ArticleForum Post: RE: Error 2760 installing Prerequisite
Hi Ivan, Can you please provide some images of the error message. Regards, Swapnil Joshi
View ArticleForum Post: RE: Spec Break orientation OPPID
Hello Nuno, Do you want something like shown below image of Spec Break with Left/Right/Up/down placement? If yes, then There are properties located on the Spec Break class that need to be set to True....
View ArticleForum Post: RE: Error 2760 installing Prerequisite
Hi, These are the images of the error message. Regards, Ivan
View ArticleForum Post: RE: Error 2760 installing Prerequisite
Hi Ivan, Thank you for the images. Can you try to install CONNECTION Client manually? When you click on the apr081113211.exe it usually gets extracted in the following path as mentioned in the image....
View Article