Forum Post: RE: AP OPIM - Text message container

PROPERTY is what is used in AutoPLANT. It is used in all attached type class too, as I know.

View Article


Forum Post: RE: OPIM - default value for value mapping

Hello Maggie, EC expression is not in AutoPLANT_PDW_Property_Map custom attribute. You can try on AutoPLANT_PDW_Catalog_Property_Map, where we have option to enter ec expression as shown below. Also,...

View Article


Forum Post: RE: OPIM - default value for value mapping

Hi Deepak, I can add a new attribute with what you describe, but can you please give more details on how I should write a ECExpression to have a default value and the mean time doing a mapping? Thanks,...

View Article

File: AXSYS.Process Readme CONNECT Edition Update 1

Hi, The readme for the AXSYS.Process CONNECT Edition Update 1 is in the attached zip file. Thanks, Tim Lawrence Product Manager

View Article

Wiki Page: AutoPLANT project versions and OpenPlant Isometrics Manager Support

Applies To Product(s): AutoPLANT Modeler Version(s): Environment: N/A Area: Subarea: N/A Original Author: Keith Couvillion, Bentley Product Advantage Group Which AutoPLANT project versions are...

View Article


Wiki Page: How to represent the flex hose in OpenPlant Isometrics Manager.

Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.224 (SS6) Environment: Windows 7/8.1/10 (64 bit) & others Area: Settings/Attributes Subarea: Isometric Content - Annotation...

View Article

Wiki Page: Understanding Component Preferences In AutoPLANT [TN]

Applies To Product(s): AutoPLANT Plant Design Version(s): XM Edition Environment: N/A Area: N/A Subarea: N/A Original Author: Jesse Wolfe, Bentley Product Advantage Group Overview Many new features...

View Article

Forum Post: OP OPIM - 08.11.11.103 download

Hi, Where can I get OPIM 08.11.11.103? The Download Section only shows: 08.11.09.470 08.11.11.224 08.11.11.277 08.11.11.285 Also is 08.11.11.285 the Refresh 4 that is applicable to AP (mentioned as...

View Article


Forum Post: OPIM 08.11.11.277 - BOM droped into individual text elements on...

Hi, Is there a setting that stops OPIM 08.11.11.277 dropping BOM into individual text elements and placed them onto Default level. Best regards, Tuan

View Article


Forum Post: RE: OP OPIM - 08.11.11.103 download

Hello Tuan Le, Yes you could download the latest 08.11.11.285, equally suitable for OpenPlant Modeler. HTH, -Regards | Rahul Kumar

View Article

Forum Post: RE: OPIM 08.11.11.277 - BOM droped into individual text elements...

Hello Tuan Le, Can you please elaborate a situation with some image? Also please test the case with latest 08.11.11.285 -Regards | Rahul Kumar

View Article

Forum Post: OPM SS6 - Multiple inlet outlet ratings on relief valve

Hi, Refering to the wiki article below https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/17003/how-to-set-inlet-outlet-ratings-on-relief-valve Is there a way to...

View Article

Forum Post: RE: OPM SS6 - Multiple inlet outlet ratings on relief valve

Hello Tuan Le, Using default settings would not allow such behaviour. Can you check with out of the box projects? -Regards | Rahul Kumar

View Article


Forum Post: RE: OPM SS6 - Multiple inlet outlet ratings on relief valve

Hi Rahul, We haven't implement the modification in the mentioned wiki yet. My apology for not being clear with my original question. The issue is we do have a relief valve with 300lb inlet and 150lb...

View Article

Forum Post: RE: OP OPIM - 08.11.11.103 download

Thanks Rahul, any advice on 08.11.11.103 availability?

View Article


Forum Post: RE: OP OPIM - 08.11.11.103 download

Hi Tuan, As Rahul mentioned that you can use latest version of OPIM 08.11.11.285 with OPM. if you have some specific requirement to use OPIM 08.11.11.103 then do let us know so that we can provide you...

View Article

Forum Post: RE: OPIM 08.11.11.277 - BOM droped into individual text elements...

We have found the same issue, there has been a Bentley enhancement ticket started #652602. I was told this is a request from Users, why anyone would want this is beyond me.

View Article


Forum Post: RE: OPIM 08.11.11.277 - BOM droped into individual text elements...

I'm alright with having the BOM exploded into pieces. However, it seems the BOM text node is also moved the active level of the seed file in the process, which threw out our standard check. I haven't...

View Article

Forum Post: OPM 08.11.11.277 - "Create isos directly from an OpenPlant...

Hi, Just saw this in the new feature list. Can I get some elaboration on what this means and a tutorial perhaps? Best regards, Tuan

View Article

Forum Post: RE: OPM 08.11.11.277 - "Create isos directly from an OpenPlant...

Hi Tuan, This feature is added to reduce time for isometrics output generation & increase efficiency. In OpenPlant Modeler, in Pipeline Manager Dialog, an icon for "create iso directly" has been...