Forum Post: RE: AP OPIM - Text message container
PROPERTY is what is used in AutoPLANT. It is used in all attached type class too, as I know.
View ArticleForum Post: RE: OPIM - default value for value mapping
Hello Maggie, EC expression is not in AutoPLANT_PDW_Property_Map custom attribute. You can try on AutoPLANT_PDW_Catalog_Property_Map, where we have option to enter ec expression as shown below. Also,...
View ArticleForum Post: RE: OPIM - default value for value mapping
Hi Deepak, I can add a new attribute with what you describe, but can you please give more details on how I should write a ECExpression to have a default value and the mean time doing a mapping? Thanks,...
View ArticleFile: AXSYS.Process Readme CONNECT Edition Update 1
Hi, The readme for the AXSYS.Process CONNECT Edition Update 1 is in the attached zip file. Thanks, Tim Lawrence Product Manager
View ArticleWiki Page: AutoPLANT project versions and OpenPlant Isometrics Manager Support
Applies To Product(s): AutoPLANT Modeler Version(s): Environment: N/A Area: Subarea: N/A Original Author: Keith Couvillion, Bentley Product Advantage Group Which AutoPLANT project versions are...
View ArticleWiki Page: How to represent the flex hose in OpenPlant Isometrics Manager.
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.224 (SS6) Environment: Windows 7/8.1/10 (64 bit) & others Area: Settings/Attributes Subarea: Isometric Content - Annotation...
View ArticleWiki Page: Understanding Component Preferences In AutoPLANT [TN]
Applies To Product(s): AutoPLANT Plant Design Version(s): XM Edition Environment: N/A Area: N/A Subarea: N/A Original Author: Jesse Wolfe, Bentley Product Advantage Group Overview Many new features...
View ArticleForum Post: OP OPIM - 08.11.11.103 download
Hi, Where can I get OPIM 08.11.11.103? The Download Section only shows: 08.11.09.470 08.11.11.224 08.11.11.277 08.11.11.285 Also is 08.11.11.285 the Refresh 4 that is applicable to AP (mentioned as...
View ArticleForum Post: OPIM 08.11.11.277 - BOM droped into individual text elements on...
Hi, Is there a setting that stops OPIM 08.11.11.277 dropping BOM into individual text elements and placed them onto Default level. Best regards, Tuan
View ArticleForum Post: RE: OP OPIM - 08.11.11.103 download
Hello Tuan Le, Yes you could download the latest 08.11.11.285, equally suitable for OpenPlant Modeler. HTH, -Regards | Rahul Kumar
View ArticleForum Post: RE: OPIM 08.11.11.277 - BOM droped into individual text elements...
Hello Tuan Le, Can you please elaborate a situation with some image? Also please test the case with latest 08.11.11.285 -Regards | Rahul Kumar
View ArticleForum Post: OPM SS6 - Multiple inlet outlet ratings on relief valve
Hi, Refering to the wiki article below https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/17003/how-to-set-inlet-outlet-ratings-on-relief-valve Is there a way to...
View ArticleForum Post: RE: OPM SS6 - Multiple inlet outlet ratings on relief valve
Hello Tuan Le, Using default settings would not allow such behaviour. Can you check with out of the box projects? -Regards | Rahul Kumar
View ArticleForum Post: RE: OPM SS6 - Multiple inlet outlet ratings on relief valve
Hi Rahul, We haven't implement the modification in the mentioned wiki yet. My apology for not being clear with my original question. The issue is we do have a relief valve with 300lb inlet and 150lb...
View ArticleForum Post: RE: OP OPIM - 08.11.11.103 download
Thanks Rahul, any advice on 08.11.11.103 availability?
View ArticleForum Post: RE: OP OPIM - 08.11.11.103 download
Hi Tuan, As Rahul mentioned that you can use latest version of OPIM 08.11.11.285 with OPM. if you have some specific requirement to use OPIM 08.11.11.103 then do let us know so that we can provide you...
View ArticleForum Post: RE: OPIM 08.11.11.277 - BOM droped into individual text elements...
We have found the same issue, there has been a Bentley enhancement ticket started #652602. I was told this is a request from Users, why anyone would want this is beyond me.
View ArticleForum Post: RE: OPIM 08.11.11.277 - BOM droped into individual text elements...
I'm alright with having the BOM exploded into pieces. However, it seems the BOM text node is also moved the active level of the seed file in the process, which threw out our standard check. I haven't...
View ArticleForum Post: OPM 08.11.11.277 - "Create isos directly from an OpenPlant...
Hi, Just saw this in the new feature list. Can I get some elaboration on what this means and a tutorial perhaps? Best regards, Tuan
View ArticleForum Post: RE: OPM 08.11.11.277 - "Create isos directly from an OpenPlant...
Hi Tuan, This feature is added to reduce time for isometrics output generation & increase efficiency. In OpenPlant Modeler, in Pipeline Manager Dialog, an icon for "create iso directly" has been...
View Article