Forum Post: AutoPLANT SS7 - Xchg pcf export - Continuing Components issue

When trying to create a PCF file via "Plant Exchange --> PCF --> Generate PCF" function, if "Continuing Components" is set to 0, exporting process runs smoothly with no error. However, if...

View Article


Forum Post: RE: OPIM - Hatch and slope display threshold

Thanks Rahul, but the wiki only talk about display styles and no slope display limit is mentioned.

View Article


Wiki Page: AutoPLANT with OpenPlant Isometrics Manager

Issues related to AutoPLANT with OpenPlant Isometrics Manager...

View Article

Forum Post: RE: Drawing Files size has increased in OpenPlant

Hi Harpreet The file is too big for the server to handle even zipped. Regards Steve

View Article

Forum Post: RE: AutoPLANT Object Enablers for AutoCAD 2017

Hi, To further update on this, you can expect OE for AutoCAD 2017 by end of this year. HTH, -Regards | Rahul Kumar

View Article


Forum Post: RE: OPIM - Tag/Text, Part ID and Coordination

Hello Maggie, This has not been implemented yet with latest OpenPlant Isometrics Manager version. Please create an SR to enable us to log this issue. -Regards | Rahul Kumar

View Article

Forum Post: RE: Importing a MODEL from access to SQL

Hello Guy Guerir, Normally following steps followed to convert access database project to SQl database. 1. Create project package of access database project through project packager utility. 2....

View Article

Forum Post: RE: OPIM_AT, Reference Dimension, Carriage return

Hello Stephane, Could you please log service request for this issue, so that we can log defect. Looking forward to your reply. Regards, Abhijit Bute

View Article


Forum Post: RE: OPIM - Isometric with Tee Shoe Support takes forever

Hello Stephane, Could you please log service request for this issue, so that i can log defect. Looking forward to your reply. Regards, Abhijit Bute

View Article


Forum Post: RE: Drawing Files size has increased in OpenPlant

Hi Steve, Please upload the file on below link: bentley.sharefile.com/r-r9cbe3f094454c169 Regards, Harpreet

View Article

Wiki Page: How to Add Multiple Views in a Single View Arrangement Definition...

Applies To Product(s): OpenPlant Orthographics Manager Version(s): 08.11.11.87 (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: View Arrangement Definition File Subarea: Add Multiple Views Original...

View Article

Forum Post: RE: AutoPLANT SS7 - Xchg pcf export - Continuing Components issue

Hello Maggie, I will check your concern and get back to you. Regards, Abhijit Bute

View Article

Wiki Page: Selected Spec is Incompatible With the Current Project

Applies To Product(s): OpenPlant Modeler Version(s): 08.11.11.87 (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: OpenPlant Specification Generator Subarea: Specs Loading Original Author: Faisal...

View Article


Wiki Page: How to Edit Seed File in OPenPlant PID Without MicroStation

Applies To Product(s): OpenPlant PID Version(s): 08.11.11.43 (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Configuration Subarea: Original Author: Faisal Khan, Bentley Product Advantage Group To...

View Article

Wiki Page: Isometric Fails with “Error [0]: Unable to Locate ADDON (4) to...

Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 (64 bit) Area: Settings/Attributes Subarea: Original Author: Abhijit Bute, Bentley Product Advantage...

View Article


Forum Post: RE: AutoPLANT SS7 - Xchg pcf export - Continuing Components issue

Hello Maggie, We already logged defect for this issue. Could you please raise service request, so that I can link service request to existing defect. Waiting for your reply. Regards, Abhijit Bute

View Article

Wiki Page: How to Delete View(s) from View Arrangement Definition (VAD) File

Applies To Product(s): OpenPlant Orthographics Manager Version(s): 08.11.11.87 (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: View Arrangement Definition File Subarea: Delete View Original Author:...

View Article


Forum Post: RE: OPIM - Tapping connection sizes limitation?

Hello Maggie, I have tested same scenario on my side what I can reproduce this issue with following plug where no rating. For other plugs I can generate isometrics without any error. Are you reproduced...

View Article

Wiki Page: How to Delete a View Arrangement Definition (VAD) File in...

Applies To Product(s): OpenPlant Orthographics Manager Version(s): 08.11.11.87 (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: View Arrangement Definition (VAD) File Subarea: Delete View Arrangement...

View Article

Forum Post: RE: OPIM - Hatch and slope display threshold

Hello Maggie, For Slope, you can refer below options to explore. You can use threshold angle value and can set it to 5 degrees. HTH, -Regards | Rahul Kumar