Forum Post: Field Fit excess material isn't showing up in BOM report or Cut...
I followed this wiki: But it still isn't adding the additional material to the BOM or the cut length reports on my iso.
View ArticleComment on How to Assign FieldFit Weld Allowances or Other Weld Types for BOM...
Hello Karl, Can you check by using WA_FIELD_FIT = 6 or some other values. Also would like to request to check, if correct style has been selected(Just for confirmation). It should work. -Regards |...
View ArticleComment on How to Assign FieldFit Weld Allowances or Other Weld Types for BOM...
Yes, the correct style is selected. I tried using some other values, but It still isn't adding the additional material for field fit up.
View ArticleForum Post: RE: Isometric fittings/components lineweights
Hello Sean, Please refer below wiki article for changing the color for dimension. Also for changing the text from red to some different color, user need to change DN cell. See image below. Also check...
View ArticleForum Post: RE: How do I modify the GATSW symbol (or any valve symbol) to get...
Hello Karl, Thank you for this. One easiest way would be to copy the existing cell and re-use it by defining it with different ports like explained in below wiki. Intersection Point applies to the cell...
View ArticleForum Post: RE: How do I modify the GATSW symbol (or any valve symbol) to get...
How do I make the dimension line connect to the center of of the valve and not CP1 or CP2?
View ArticleComment on How to Assign FieldFit Weld Allowances or Other Weld Types for BOM...
Ok Thanks Karl, Can you also confirm OpenPlant Isometric Manager Version? -Regards | Rahul Kumar
View ArticleForum Post: RE: Welding list in Isometric
Hello Dmitry, Could you please try to set drawing margin as per below screen shot. Please update me result. Looking forward to your reply. Regards, Abhijit Bute
View ArticleForum Post: RE: How do I modify the GATSW symbol (or any valve symbol) to get...
Hi Karl, To Dimension from mid point of valves, you can check, "Isometric Configuration" dialog inside "Dimensioning" section. See image below. Alternatively, you can also check below wiki, where using...
View ArticleForum Post: RE: Field Fit excess material isn't showing up in BOM report or...
Hi Karl, In order to double check that you have added the settings in the correct location - open any isometric created - from the Microstation menubar select Workspace > Configuration - check that...
View ArticleForum Post: RE: Field Fit excess material isn't showing up in BOM report or...
WAS_FIELD_FIT appears in Workspace > Configuration, and under expansion shows 3, the amount of fit up material, but my BOM and cut reports still don't include this additional material. Is there...
View ArticleForum Post: RE: Field Fit excess material isn't showing up in BOM report or...
You mention WAS_FIELD_FIT where it should be WA_FIELD_FIT, could that be the issue?
View ArticleForum Post: RE: Isometric fittings/components lineweights
Thanks Rahul, Do you know how to solve the issue I am having with valve handles (in my last post, above)? Kind Regards, Sean
View ArticleForum Post: RE: Isometric fittings/components lineweights
Hi Sean, The valve operator can currently not be singled out using the include/exclude statements wrt overrides. The only option is to go into the cell library and change the weight Regards, Frank
View ArticleForum Post: RE: Field Fit excess material isn't showing up in BOM report or...
That's just my poor spelling in the replay, OPIM shows WA_FIELD_FIT.
View ArticleForum Post: RE: Field Fit excess material isn't showing up in BOM report or...
Fair enough :). lets do a check now for the correct type. If you use the Show Tag Tool on the weld of interest (in DGN mode) look at the following properties: TYPE It should list FIELD_FIT. If it is...
View ArticleWiki Page: Isometric successfully, but PCF generation failed Message in...
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.440 & Above Environment: Windows 7 (64 bit) Area: Settings/Attributes Subarea: Original Author: Rahul Kumar, Bentley Product...
View ArticleWiki Page: Errors, Logs, Messages, Crashes - OpenPlant Isometrics Manager
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX & Others Environment: Windows 7 (64 bit) Area: - Subarea: - Original Author: Bentley Product Advantage Group Isometrics...
View ArticleForum Post: RE: I get Error When I Generate Isometric With I-model file. Also...
Open Plant Modeller V8i (SELECT series 5) 08.11.09.568, Open Plant Isometric Manager V8i (SELECT series 5) 08.11.09.564 Open Plant Project Administrator V8i (Select Series 5) Hope u get Information...
View Article