Forum Post: Field Fit excess material isn't showing up in BOM report or Cut...

I followed this wiki: But it still isn't adding the additional material to the BOM or the cut length reports on my iso.

View Article


Comment on How to Assign FieldFit Weld Allowances or Other Weld Types for BOM...

Hello Karl, Can you check by using WA_FIELD_FIT = 6 or some other values. Also would like to request to check, if correct style has been selected(Just for confirmation). It should work. -Regards |...

View Article


Comment on How to Assign FieldFit Weld Allowances or Other Weld Types for BOM...

Yes, the correct style is selected. I tried using some other values, but It still isn't adding the additional material for field fit up.

View Article

Forum Post: RE: Isometric fittings/components lineweights

Hello Sean, Please refer below wiki article for changing the color for dimension. Also for changing the text from red to some different color, user need to change DN cell. See image below. Also check...

View Article

Forum Post: RE: How do I modify the GATSW symbol (or any valve symbol) to get...

Hello Karl, Thank you for this. One easiest way would be to copy the existing cell and re-use it by defining it with different ports like explained in below wiki. Intersection Point applies to the cell...

View Article


Forum Post: RE: How do I modify the GATSW symbol (or any valve symbol) to get...

How do I make the dimension line connect to the center of of the valve and not CP1 or CP2?

View Article

Comment on How to Assign FieldFit Weld Allowances or Other Weld Types for BOM...

Ok Thanks Karl, Can you also confirm OpenPlant Isometric Manager Version? -Regards | Rahul Kumar

View Article

Comment on How to Assign FieldFit Weld Allowances or Other Weld Types for BOM...

08.11.09.470

View Article


Forum Post: RE: Welding list in Isometric

Hello Dmitry, Could you please try to set drawing margin as per below screen shot. Please update me result. Looking forward to your reply. Regards, Abhijit Bute

View Article


Forum Post: RE: How do I modify the GATSW symbol (or any valve symbol) to get...

Hi Karl, To Dimension from mid point of valves, you can check, "Isometric Configuration" dialog inside "Dimensioning" section. See image below. Alternatively, you can also check below wiki, where using...

View Article

Forum Post: RE: Field Fit excess material isn't showing up in BOM report or...

Hi Karl, In order to double check that you have added the settings in the correct location - open any isometric created - from the Microstation menubar select Workspace > Configuration - check that...

View Article

Forum Post: RE: Field Fit excess material isn't showing up in BOM report or...

WAS_FIELD_FIT appears in Workspace > Configuration, and under expansion shows 3, the amount of fit up material, but my BOM and cut reports still don't include this additional material. Is there...

View Article

Forum Post: RE: Field Fit excess material isn't showing up in BOM report or...

You mention WAS_FIELD_FIT where it should be WA_FIELD_FIT, could that be the issue?

View Article


Forum Post: RE: Isometric fittings/components lineweights

Thanks Rahul, Do you know how to solve the issue I am having with valve handles (in my last post, above)? Kind Regards, Sean

View Article

Forum Post: RE: Isometric fittings/components lineweights

Hi Sean, The valve operator can currently not be singled out using the include/exclude statements wrt overrides. The only option is to go into the cell library and change the weight Regards, Frank

View Article


Forum Post: RE: Field Fit excess material isn't showing up in BOM report or...

That's just my poor spelling in the replay, OPIM shows WA_FIELD_FIT.

View Article

Forum Post: RE: Field Fit excess material isn't showing up in BOM report or...

Fair enough :). lets do a check now for the correct type. If you use the Show Tag Tool on the weld of interest (in DGN mode) look at the following properties: TYPE It should list FIELD_FIT. If it is...

View Article


Wiki Page: Isometric successfully, but PCF generation failed Message in...

Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.440 & Above Environment: Windows 7 (64 bit) Area: Settings/Attributes Subarea: Original Author: Rahul Kumar, Bentley Product...

View Article

Wiki Page: Errors, Logs, Messages, Crashes - OpenPlant Isometrics Manager

Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX & Others Environment: Windows 7 (64 bit) Area: - Subarea: - Original Author: Bentley Product Advantage Group Isometrics...

View Article

Forum Post: RE: I get Error When I Generate Isometric With I-model file. Also...

Open Plant Modeller V8i (SELECT series 5) 08.11.09.568, Open Plant Isometric Manager V8i (SELECT series 5) 08.11.09.564 Open Plant Project Administrator V8i (Select Series 5) Hope u get Information...

View Article