Wiki Page: Exchange the Coordinates in OpenPlant Isometrics Manager CONNECT Edition

Applies To Product(s): OpenPlant Isometrics Manager Version(s): CONNECT Edition Update 11 (10.XX.XX.XXX) Environment: Windows 10 (64 bit) Area: Settings/Attributes Subarea: - Original Author: Evander Cabalagan, Bentley Global Technical Support Group Background In OpenPlant Isometrics Manager, there is a situation where the user wants to exchange the position of coordinates based on standard or requirement. The goal can be achieved by fixing the configuration in style.cfg file. Steps to Accomplish Open style.cfg file in preferred isometric style by selecting the appropriate Workspace and Workset. Locate IE_COORD_SWAP in style.cfg. By default, the value is zero, that is why it follows the E/N/EL order in generated isometrics. Change the value into 1. Save and close the style.cfg file. Generate the isometrics to verify the result. See Also communities.bentley.com/.../errors-logs-messages-crashes-in-connect---openplant-isometrics-manager Comments or Corrections? Bentley's Global Technical Support group requests that you please confine any comments you have on this Wiki entry to Forum section? section. THANK YOU! communities.bentley.com/.../autoplant-axsys-openplant-plantwise-forum